A Biomechanical Study of Periacetabular Defects and Cement FillingSource: Journal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 002::page 129Author:Zuoping Li
,
Herrick J. Siegel
,
Jack E. Lemons
,
Alan W. Eberhardt
,
Neha B. Butala
,
Brandon S. Etheridge
DOI: 10.1115/1.2472367Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Periacetabular bone metastases cause severe pain and functional disability in cancer patients. Percutaneous acetabuloplasty (PCA) is a minimally invasive, image-guided procedure whereby cement is injected into lesion sites. Pain relief and functional restoration have been observed clinically; however, neither the biomechanical consequences of the lesions nor the effectiveness of the PCA technique are well understood. The objective of this study was to investigate how periacetabular lesion size, cortex involvement, and cement modulus affect pelvic bone stresses and strains under single-legged stance loading. Experiments were performed on a male cadaver pelvis under conditions of intact, periacetabular defect, and cement-filling with surface strains recorded at three strain gage locations. The experimental data were then employed to validate three-dimensional finite element models of the same pelvis, developed using computed tomography data. The models demonstrated that increases in cortical stresses were highest along the posterior column of the acetabulum, adjacent to the defect. Cortical stresses were more profoundly affected in the presence of transcortical defects, as compared to those involving only trabecular bone. Cement filling with a modulus of 2.2GPa was shown to restore cortical stresses to near intact values, while a decrease in cement modulus due to inclusion of BaSO4 reduced the restorative effect. Peak acetabular contact pressures increased less than 15% for all simulated defect conditions; however, the contact stresses were reduced to levels below intact in the presence of either cement filling. These results suggest that periacetabular defects may increase the vulnerability of the pelvis to fracture depending on size and cortical involvement and that PCA filling may lower the risk of periacetabular fractures.
|
Collections
Show full item record
| contributor author | Zuoping Li | |
| contributor author | Herrick J. Siegel | |
| contributor author | Jack E. Lemons | |
| contributor author | Alan W. Eberhardt | |
| contributor author | Neha B. Butala | |
| contributor author | Brandon S. Etheridge | |
| date accessioned | 2017-05-09T00:22:48Z | |
| date available | 2017-05-09T00:22:48Z | |
| date copyright | April, 2007 | |
| date issued | 2007 | |
| identifier issn | 0148-0731 | |
| identifier other | JBENDY-26680#129_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/135272 | |
| description abstract | Periacetabular bone metastases cause severe pain and functional disability in cancer patients. Percutaneous acetabuloplasty (PCA) is a minimally invasive, image-guided procedure whereby cement is injected into lesion sites. Pain relief and functional restoration have been observed clinically; however, neither the biomechanical consequences of the lesions nor the effectiveness of the PCA technique are well understood. The objective of this study was to investigate how periacetabular lesion size, cortex involvement, and cement modulus affect pelvic bone stresses and strains under single-legged stance loading. Experiments were performed on a male cadaver pelvis under conditions of intact, periacetabular defect, and cement-filling with surface strains recorded at three strain gage locations. The experimental data were then employed to validate three-dimensional finite element models of the same pelvis, developed using computed tomography data. The models demonstrated that increases in cortical stresses were highest along the posterior column of the acetabulum, adjacent to the defect. Cortical stresses were more profoundly affected in the presence of transcortical defects, as compared to those involving only trabecular bone. Cement filling with a modulus of 2.2GPa was shown to restore cortical stresses to near intact values, while a decrease in cement modulus due to inclusion of BaSO4 reduced the restorative effect. Peak acetabular contact pressures increased less than 15% for all simulated defect conditions; however, the contact stresses were reduced to levels below intact in the presence of either cement filling. These results suggest that periacetabular defects may increase the vulnerability of the pelvis to fracture depending on size and cortical involvement and that PCA filling may lower the risk of periacetabular fractures. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Biomechanical Study of Periacetabular Defects and Cement Filling | |
| type | Journal Paper | |
| journal volume | 129 | |
| journal issue | 2 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.2472367 | |
| journal fristpage | 129 | |
| journal lastpage | 136 | |
| identifier eissn | 1528-8951 | |
| tree | Journal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 002 | |
| contenttype | Fulltext |