Geometric Design of Three-Phalanx Underactuated FingersSource: Journal of Mechanical Design:;2006:;volume( 128 ):;issue: 002::page 356DOI: 10.1115/1.2159029Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This paper studies the grasp stability of two classes of three-phalanx underactuated fingers with transmission mechanisms based on either linkages or tendons and pulleys. The concept of underactuation in robotic fingers—with fewer actuators than degrees of freedom—allows the hand to adjust itself to an irregularly shaped object without complex control strategy and sensors. With a n-phalanx finger, n contacts (one for each phalanx) are normally required to statically constrain the finger. However, some contact forces may be lacking due to either the transmission mechanism, or simply the object size and position. Thus, one may define an ith order equilibrium, when the finger is in static equilibrium with i missing contacts. In this paper, the case for which n=3 is studied with a particular emphasis on the cases for which i=1 and i=2. The fact that some contact forces do not appear or are negative, can lead in some cases to the ejection of the object from the hand, when no equilibrium configuration is achieved.
keyword(s): Force , Stability , Motion , Equilibrium (Physics) , Linkages , Design , Tendons , Trajectories (Physics) , Pulleys , Equations AND Actuators ,
|
Collections
Show full item record
| contributor author | Lionel Birglen | |
| contributor author | Clément M. Gosselin | |
| date accessioned | 2017-05-09T00:21:03Z | |
| date available | 2017-05-09T00:21:03Z | |
| date copyright | March, 2006 | |
| date issued | 2006 | |
| identifier issn | 1050-0472 | |
| identifier other | JMDEDB-27824#356_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/134349 | |
| description abstract | This paper studies the grasp stability of two classes of three-phalanx underactuated fingers with transmission mechanisms based on either linkages or tendons and pulleys. The concept of underactuation in robotic fingers—with fewer actuators than degrees of freedom—allows the hand to adjust itself to an irregularly shaped object without complex control strategy and sensors. With a n-phalanx finger, n contacts (one for each phalanx) are normally required to statically constrain the finger. However, some contact forces may be lacking due to either the transmission mechanism, or simply the object size and position. Thus, one may define an ith order equilibrium, when the finger is in static equilibrium with i missing contacts. In this paper, the case for which n=3 is studied with a particular emphasis on the cases for which i=1 and i=2. The fact that some contact forces do not appear or are negative, can lead in some cases to the ejection of the object from the hand, when no equilibrium configuration is achieved. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Geometric Design of Three-Phalanx Underactuated Fingers | |
| type | Journal Paper | |
| journal volume | 128 | |
| journal issue | 2 | |
| journal title | Journal of Mechanical Design | |
| identifier doi | 10.1115/1.2159029 | |
| journal fristpage | 356 | |
| journal lastpage | 364 | |
| identifier eissn | 1528-9001 | |
| keywords | Force | |
| keywords | Stability | |
| keywords | Motion | |
| keywords | Equilibrium (Physics) | |
| keywords | Linkages | |
| keywords | Design | |
| keywords | Tendons | |
| keywords | Trajectories (Physics) | |
| keywords | Pulleys | |
| keywords | Equations AND Actuators | |
| tree | Journal of Mechanical Design:;2006:;volume( 128 ):;issue: 002 | |
| contenttype | Fulltext |