    One-Way Air Chambers for Pumping Plants

    Source: Journal of Fluids Engineering:;1969:;volume( 091 ):;issue: 003::page 383
    Author:
    J. T. Kephart
    DOI: 10.1115/1.3571127
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The one-way air chamber for suppressing water-column separation is described. Operation of the one-way air chamber during a power failure transient is explained. A typical problem solution is shown. The one-way air chamber is compared with the one-way surge tank and the normal air chamber.
    keyword(s): Separation (Technology) , Failure , Industrial plants , Surges AND Water ,
    • Download: (750.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      One-Way Air Chambers for Pumping Plants

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/134345
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorJ. T. Kephart
    date accessioned2017-05-09T00:21:02Z
    date available2017-05-09T00:21:02Z
    date copyrightSeptember, 1969
    date issued1969
    identifier issn0098-2202
    identifier otherJFEGA4-27339#383_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/134345
    description abstractThe one-way air chamber for suppressing water-column separation is described. Operation of the one-way air chamber during a power failure transient is explained. A typical problem solution is shown. The one-way air chamber is compared with the one-way surge tank and the normal air chamber.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleOne-Way Air Chambers for Pumping Plants
    typeJournal Paper
    journal volume91
    journal issue3
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3571127
    journal fristpage383
    journal lastpage385
    identifier eissn1528-901X
    keywordsSeparation (Technology)
    keywordsFailure
    keywordsIndustrial plants
    keywordsSurges AND Water
    treeJournal of Fluids Engineering:;1969:;volume( 091 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian