    Inherently Linear Annular-Duct-Type Laminar Flowmeter

    Source: Journal of Fluids Engineering:;2006:;volume( 128 ):;issue: 001::page 196
    Author:
    Janusz Wojtkowiak
    ,
    Czeslaw O. Popiel
    DOI: 10.1115/1.2137347
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A concept of the laminar flowmeter is based on the well-known relationship between laminar flow rate of fluid Q through a measuring element of length L and pressure drop ΔP. Usually the measuring element is a capillary tube, capillary tube bundle, parallel plate bundle, or concentric annular duct (Fig. 1).
    keyword(s): Flowmeters , Reynolds number , Ducts , Flow (Dynamics) , Pressure AND Pressure drop ,
    • Download: (92.10Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Inherently Linear Annular-Duct-Type Laminar Flowmeter

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/134004
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorJanusz Wojtkowiak
    contributor authorCzeslaw O. Popiel
    date accessioned2017-05-09T00:20:26Z
    date available2017-05-09T00:20:26Z
    date copyrightJanuary, 2006
    date issued2006
    identifier issn0098-2202
    identifier otherJFEGA4-27214#196_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/134004
    description abstractA concept of the laminar flowmeter is based on the well-known relationship between laminar flow rate of fluid Q through a measuring element of length L and pressure drop ΔP. Usually the measuring element is a capillary tube, capillary tube bundle, parallel plate bundle, or concentric annular duct (Fig. 1).
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInherently Linear Annular-Duct-Type Laminar Flowmeter
    typeJournal Paper
    journal volume128
    journal issue1
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.2137347
    journal fristpage196
    journal lastpage198
    identifier eissn1528-901X
    keywordsFlowmeters
    keywordsReynolds number
    keywordsDucts
    keywordsFlow (Dynamics)
    keywordsPressure AND Pressure drop
    treeJournal of Fluids Engineering:;2006:;volume( 128 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian