Corrosion Fatigue in Surgical ImplantsSource: Journal of Fluids Engineering:;1969:;volume( 091 ):;issue: 004::page 581Author:V. J. Colangelo
DOI: 10.1115/1.3571192Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Orthopedic appliances of type 316 SMO were examined after removal from human subjects. Fractographic evidence, macroscopic and microscopic, is presented together with the overall incidence of fracture and fatigue for the specimens examined. Bend fatigue tests were conducted in air and in isotonic saline solution (0.9 percent NaCl) and the crack-growth rates determined. Data followed the empirical relationship proposed by Paris [5]: da/dN = C(Δ K)m with m rising from 3.23 in air to 4.16 for isotonic saline. A distinct change in the appearance of the fracture surface was noted on the specimens broken in the saline environment. The specimens broken in air were bright, while the specimens fatigued in 0.9 percent NaCl were darkened with corrosion products.
keyword(s): Fatigue , Corrosion , Surgery , Fracture (Process) , Fatigue testing AND Orthopedics ,
|
Collections
Show full item record
| contributor author | V. J. Colangelo | |
| date accessioned | 2017-05-09T00:19:53Z | |
| date available | 2017-05-09T00:19:53Z | |
| date copyright | December, 1969 | |
| date issued | 1969 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-27348#581_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/133701 | |
| description abstract | Orthopedic appliances of type 316 SMO were examined after removal from human subjects. Fractographic evidence, macroscopic and microscopic, is presented together with the overall incidence of fracture and fatigue for the specimens examined. Bend fatigue tests were conducted in air and in isotonic saline solution (0.9 percent NaCl) and the crack-growth rates determined. Data followed the empirical relationship proposed by Paris [5]: da/dN = C(Δ K)m with m rising from 3.23 in air to 4.16 for isotonic saline. A distinct change in the appearance of the fracture surface was noted on the specimens broken in the saline environment. The specimens broken in air were bright, while the specimens fatigued in 0.9 percent NaCl were darkened with corrosion products. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Corrosion Fatigue in Surgical Implants | |
| type | Journal Paper | |
| journal volume | 91 | |
| journal issue | 4 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.3571192 | |
| journal fristpage | 581 | |
| journal lastpage | 586 | |
| identifier eissn | 1528-901X | |
| keywords | Fatigue | |
| keywords | Corrosion | |
| keywords | Surgery | |
| keywords | Fracture (Process) | |
| keywords | Fatigue testing AND Orthopedics | |
| tree | Journal of Fluids Engineering:;1969:;volume( 091 ):;issue: 004 | |
| contenttype | Fulltext |