    An Optimized Image Matching Method for Determining In-Vivo TKA Kinematics with a Dual-Orthogonal Fluoroscopic Imaging System

    Source: Journal of Biomechanical Engineering:;2006:;volume( 128 ):;issue: 004::page 588
    Author:
    Jeffrey Bingham
    ,
    Guoan Li
    DOI: 10.1115/1.2205865
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This study presents an optimized matching algorithm for a dual-orthogonal fluoroscopic image system used to determine six degrees-of-freedom total knee arthroplasty (TKA) kinematics in-vivo. The algorithm was evaluated using controlled conditions and standard geometries. Results of the validation demonstrate the algorithm’s robustness and capability of realizing a pose from a variety of initial poses. Under idealized conditions, poses of a TKA system were recreated to within 0.02±0.01 mm and 0.02±0.03 deg for the femoral component and 0.07±0.09 mm and 0.16±0.18 deg for the tibial component. By employing a standardized geometry with spheres, the translational accuracy and repeatability under actual conditions was found to be 0.01±0.06 mm. Application of the optimized matching algorithm to a TKA patient showed that the pose of in-vivo TKA components can be repeatedly located, with standard deviations less than ±0.12 mm and ±0.12 deg for the femoral component and ±0.29 mm and ±0.25 deg for the tibial component. This methodology presents a useful tool that can be readily applied to the investigation of in-vivo motion of TKA kinematics.
    keyword(s): Kinematics , Algorithms , Testing , Knee , Imaging , Geometry , Errors , Optimization AND Arthroplasty ,
    • Download: (478.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      An Optimized Image Matching Method for Determining In-Vivo TKA Kinematics with a Dual-Orthogonal Fluoroscopic Imaging System

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/133182
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorJeffrey Bingham
    contributor authorGuoan Li
    date accessioned2017-05-09T00:18:55Z
    date available2017-05-09T00:18:55Z
    date copyrightAugust, 2006
    date issued2006
    identifier issn0148-0731
    identifier otherJBENDY-26601#588_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/133182
    description abstractThis study presents an optimized matching algorithm for a dual-orthogonal fluoroscopic image system used to determine six degrees-of-freedom total knee arthroplasty (TKA) kinematics in-vivo. The algorithm was evaluated using controlled conditions and standard geometries. Results of the validation demonstrate the algorithm’s robustness and capability of realizing a pose from a variety of initial poses. Under idealized conditions, poses of a TKA system were recreated to within 0.02±0.01 mm and 0.02±0.03 deg for the femoral component and 0.07±0.09 mm and 0.16±0.18 deg for the tibial component. By employing a standardized geometry with spheres, the translational accuracy and repeatability under actual conditions was found to be 0.01±0.06 mm. Application of the optimized matching algorithm to a TKA patient showed that the pose of in-vivo TKA components can be repeatedly located, with standard deviations less than ±0.12 mm and ±0.12 deg for the femoral component and ±0.29 mm and ±0.25 deg for the tibial component. This methodology presents a useful tool that can be readily applied to the investigation of in-vivo motion of TKA kinematics.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Optimized Image Matching Method for Determining In-Vivo TKA Kinematics with a Dual-Orthogonal Fluoroscopic Imaging System
    typeJournal Paper
    journal volume128
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2205865
    journal fristpage588
    journal lastpage595
    identifier eissn1528-8951
    keywordsKinematics
    keywordsAlgorithms
    keywordsTesting
    keywordsKnee
    keywordsImaging
    keywordsGeometry
    keywordsErrors
    keywordsOptimization AND Arthroplasty
    treeJournal of Biomechanical Engineering:;2006:;volume( 128 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian