A Comparison of X-Ray Microdiffraction and Coherent Gradient Sensing in Measuring Discontinuous Curvatures in Thin Film: Substrate SystemsSource: Journal of Applied Mechanics:;2006:;volume( 073 ):;issue: 005::page 723Author:Michal A. Brown
,
Tae-Soon Park
,
Ares Rosakis
,
Ersan Ustundag
,
Young Huang
,
Nobumichi Tamura
,
Bryan Valek
DOI: 10.1115/1.2150500Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The coherent gradient sensor (CGS) is a shearing interferometer which has been proposed for the rapid, full-field measurement of deformation states (slopes and curvatures) in thin film-wafer substrate systems, and for the subsequent inference of stresses in the thin films. This approach needs to be verified using a more well-established but time-consuming grain orientation and stress measurement tool, X-ray microdiffraction (XRD). Both CGS and XRD are used to measure the deformation state of the same W film/Si wafer at room temperature. CGS provides a global, wafer-level measurement of slopes while XRD provides a local micromeasurement of lattice rotations. An extreme case of a circular Si wafer with a circular W film island in its center is used because of the presence of discontinuous system curvatures across the wafer. The results are also compared with a theoretical model based on elastic plate analysis of the axisymmetric biomaterial film-substrate system. Slope and curvature measurements by XRD and by CGS compare very well with each other and with theory. The favorable comparison demonstrates that wafer-level CGS metrology provides a quick and accurate alternative to other measurements. It also demonstrates the accuracy of plate theory in modeling thin film-substrate systems, even in the presence of curvature discontinuities
keyword(s): X-ray diffraction , Semiconductor wafers , Stress , Gradients , Thin films , Measurement AND Deformation ,
|
Collections
Show full item record
| contributor author | Michal A. Brown | |
| contributor author | Tae-Soon Park | |
| contributor author | Ares Rosakis | |
| contributor author | Ersan Ustundag | |
| contributor author | Young Huang | |
| contributor author | Nobumichi Tamura | |
| contributor author | Bryan Valek | |
| date accessioned | 2017-05-09T00:18:32Z | |
| date available | 2017-05-09T00:18:32Z | |
| date copyright | September, 2006 | |
| date issued | 2006 | |
| identifier issn | 0021-8936 | |
| identifier other | JAMCAV-26602#723_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/132989 | |
| description abstract | The coherent gradient sensor (CGS) is a shearing interferometer which has been proposed for the rapid, full-field measurement of deformation states (slopes and curvatures) in thin film-wafer substrate systems, and for the subsequent inference of stresses in the thin films. This approach needs to be verified using a more well-established but time-consuming grain orientation and stress measurement tool, X-ray microdiffraction (XRD). Both CGS and XRD are used to measure the deformation state of the same W film/Si wafer at room temperature. CGS provides a global, wafer-level measurement of slopes while XRD provides a local micromeasurement of lattice rotations. An extreme case of a circular Si wafer with a circular W film island in its center is used because of the presence of discontinuous system curvatures across the wafer. The results are also compared with a theoretical model based on elastic plate analysis of the axisymmetric biomaterial film-substrate system. Slope and curvature measurements by XRD and by CGS compare very well with each other and with theory. The favorable comparison demonstrates that wafer-level CGS metrology provides a quick and accurate alternative to other measurements. It also demonstrates the accuracy of plate theory in modeling thin film-substrate systems, even in the presence of curvature discontinuities | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Comparison of X-Ray Microdiffraction and Coherent Gradient Sensing in Measuring Discontinuous Curvatures in Thin Film: Substrate Systems | |
| type | Journal Paper | |
| journal volume | 73 | |
| journal issue | 5 | |
| journal title | Journal of Applied Mechanics | |
| identifier doi | 10.1115/1.2150500 | |
| journal fristpage | 723 | |
| journal lastpage | 729 | |
| identifier eissn | 1528-9036 | |
| keywords | X-ray diffraction | |
| keywords | Semiconductor wafers | |
| keywords | Stress | |
| keywords | Gradients | |
| keywords | Thin films | |
| keywords | Measurement AND Deformation | |
| tree | Journal of Applied Mechanics:;2006:;volume( 073 ):;issue: 005 | |
| contenttype | Fulltext |