    A Comparison of X-Ray Microdiffraction and Coherent Gradient Sensing in Measuring Discontinuous Curvatures in Thin Film: Substrate Systems

    Source: Journal of Applied Mechanics:;2006:;volume( 073 ):;issue: 005::page 723
    Author:
    Michal A. Brown
    ,
    Tae-Soon Park
    ,
    Ares Rosakis
    ,
    Ersan Ustundag
    ,
    Young Huang
    ,
    Nobumichi Tamura
    ,
    Bryan Valek
    DOI: 10.1115/1.2150500
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The coherent gradient sensor (CGS) is a shearing interferometer which has been proposed for the rapid, full-field measurement of deformation states (slopes and curvatures) in thin film-wafer substrate systems, and for the subsequent inference of stresses in the thin films. This approach needs to be verified using a more well-established but time-consuming grain orientation and stress measurement tool, X-ray microdiffraction (XRD). Both CGS and XRD are used to measure the deformation state of the same W film/Si wafer at room temperature. CGS provides a global, wafer-level measurement of slopes while XRD provides a local micromeasurement of lattice rotations. An extreme case of a circular Si wafer with a circular W film island in its center is used because of the presence of discontinuous system curvatures across the wafer. The results are also compared with a theoretical model based on elastic plate analysis of the axisymmetric biomaterial film-substrate system. Slope and curvature measurements by XRD and by CGS compare very well with each other and with theory. The favorable comparison demonstrates that wafer-level CGS metrology provides a quick and accurate alternative to other measurements. It also demonstrates the accuracy of plate theory in modeling thin film-substrate systems, even in the presence of curvature discontinuities
    keyword(s): X-ray diffraction , Semiconductor wafers , Stress , Gradients , Thin films , Measurement AND Deformation ,
    • Download: (891.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Comparison of X-Ray Microdiffraction and Coherent Gradient Sensing in Measuring Discontinuous Curvatures in Thin Film: Substrate Systems

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/132989
    Collections
    • Journal of Applied Mechanics

    Show full item record

    contributor authorMichal A. Brown
    contributor authorTae-Soon Park
    contributor authorAres Rosakis
    contributor authorErsan Ustundag
    contributor authorYoung Huang
    contributor authorNobumichi Tamura
    contributor authorBryan Valek
    date accessioned2017-05-09T00:18:32Z
    date available2017-05-09T00:18:32Z
    date copyrightSeptember, 2006
    date issued2006
    identifier issn0021-8936
    identifier otherJAMCAV-26602#723_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/132989
    description abstractThe coherent gradient sensor (CGS) is a shearing interferometer which has been proposed for the rapid, full-field measurement of deformation states (slopes and curvatures) in thin film-wafer substrate systems, and for the subsequent inference of stresses in the thin films. This approach needs to be verified using a more well-established but time-consuming grain orientation and stress measurement tool, X-ray microdiffraction (XRD). Both CGS and XRD are used to measure the deformation state of the same W film/Si wafer at room temperature. CGS provides a global, wafer-level measurement of slopes while XRD provides a local micromeasurement of lattice rotations. An extreme case of a circular Si wafer with a circular W film island in its center is used because of the presence of discontinuous system curvatures across the wafer. The results are also compared with a theoretical model based on elastic plate analysis of the axisymmetric biomaterial film-substrate system. Slope and curvature measurements by XRD and by CGS compare very well with each other and with theory. The favorable comparison demonstrates that wafer-level CGS metrology provides a quick and accurate alternative to other measurements. It also demonstrates the accuracy of plate theory in modeling thin film-substrate systems, even in the presence of curvature discontinuities
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Comparison of X-Ray Microdiffraction and Coherent Gradient Sensing in Measuring Discontinuous Curvatures in Thin Film: Substrate Systems
    typeJournal Paper
    journal volume73
    journal issue5
    journal titleJournal of Applied Mechanics
    identifier doi10.1115/1.2150500
    journal fristpage723
    journal lastpage729
    identifier eissn1528-9036
    keywordsX-ray diffraction
    keywordsSemiconductor wafers
    keywordsStress
    keywordsGradients
    keywordsThin films
    keywordsMeasurement AND Deformation
    treeJournal of Applied Mechanics:;2006:;volume( 073 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian