YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Fluids Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Fluids Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Improvements in Fixed-Valve Micropump Performance Through Shape Optimization of Valves

    Source: Journal of Fluids Engineering:;2005:;volume( 127 ):;issue: 002::page 339
    Author:
    Adrian R. Gamboa
    ,
    Christopher J. Morris
    ,
    Fred K. Forster
    DOI: 10.1115/1.1891151
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The fixed-geometry valve micropump is a seemingly simple device in which the interaction between mechanical, electrical, and fluidic components produces a maximum output near resonance. This type of pump offers advantages such as scalability, durability, and ease of fabrication in a variety of materials. Our past work focused on the development of a linear dynamic model for pump design based on maximizing resonance, while little has been done to improve valve shape. Here we present a method for optimizing valve shape using two-dimensional computational fluid dynamics in conjunction with an optimization procedure. A Tesla-type valve was optimized using a set of six independent, non-dimensional geometric design variables. The result was a 25% higher ratio of reverse to forward flow resistance (diodicity) averaged over the Reynolds number range 0<Re⩽2000 compared to calculated values for an empirically designed, commonly used Tesla-type valve shape. The optimized shape was realized with no increase in forward flow resistance. A linear dynamic model, modified to include a number of effects that limit pump performance such as cavitation, was used to design pumps based on the new valve. Prototype plastic pumps were fabricated and tested. Steady-flow tests verified the predicted improvement in diodicity. More importantly, the modest increase in diodicity resulted in measured block-load pressure and no-load flow three times higher compared to an identical pump with non-optimized valves. The large performance increase observed demonstrated the importance of valve shape optimization in the overall design process for fixed-valve micropumps.
    keyword(s): Pumps , Valves , Shapes , Optimization AND Flow (Dynamics) ,
    • Download: (1.015Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Improvements in Fixed-Valve Micropump Performance Through Shape Optimization of Valves

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/132044
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorAdrian R. Gamboa
    contributor authorChristopher J. Morris
    contributor authorFred K. Forster
    date accessioned2017-05-09T00:16:37Z
    date available2017-05-09T00:16:37Z
    date copyrightMarch, 2005
    date issued2005
    identifier issn0098-2202
    identifier otherJFEGA4-27206#339_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/132044
    description abstractThe fixed-geometry valve micropump is a seemingly simple device in which the interaction between mechanical, electrical, and fluidic components produces a maximum output near resonance. This type of pump offers advantages such as scalability, durability, and ease of fabrication in a variety of materials. Our past work focused on the development of a linear dynamic model for pump design based on maximizing resonance, while little has been done to improve valve shape. Here we present a method for optimizing valve shape using two-dimensional computational fluid dynamics in conjunction with an optimization procedure. A Tesla-type valve was optimized using a set of six independent, non-dimensional geometric design variables. The result was a 25% higher ratio of reverse to forward flow resistance (diodicity) averaged over the Reynolds number range 0<Re⩽2000 compared to calculated values for an empirically designed, commonly used Tesla-type valve shape. The optimized shape was realized with no increase in forward flow resistance. A linear dynamic model, modified to include a number of effects that limit pump performance such as cavitation, was used to design pumps based on the new valve. Prototype plastic pumps were fabricated and tested. Steady-flow tests verified the predicted improvement in diodicity. More importantly, the modest increase in diodicity resulted in measured block-load pressure and no-load flow three times higher compared to an identical pump with non-optimized valves. The large performance increase observed demonstrated the importance of valve shape optimization in the overall design process for fixed-valve micropumps.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleImprovements in Fixed-Valve Micropump Performance Through Shape Optimization of Valves
    typeJournal Paper
    journal volume127
    journal issue2
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.1891151
    journal fristpage339
    journal lastpage346
    identifier eissn1528-901X
    keywordsPumps
    keywordsValves
    keywordsShapes
    keywordsOptimization AND Flow (Dynamics)
    treeJournal of Fluids Engineering:;2005:;volume( 127 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian