    Application of “H Gas Turbine” Design Technology to Increase Thermal Efficiency and Output Capability of the Mitsubishi M701G2 Gas Turbine

    Source: Journal of Engineering for Gas Turbines and Power:;2005:;volume( 127 ):;issue: 002::page 369
    Author:
    Y. Fukuizumi
    ,
    J. Masada
    ,
    Y. Iwasaki
    ,
    V. Kallianpur
    DOI: 10.1115/1.1850490
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Mitsubishi completed design development and verification load testing of a steam-cooled M501H gas turbine at a combined cycle power plant at Takasago, Japan in 2001. Several advanced technologies were specifically developed in addition to the steam-cooled components consisting of the combustor, turbine blades, vanes, and the rotor. Some of the other key technologies consisted of an advanced compressor with a pressure ratio of 25:1, active clearance control, and advanced seal technology. Prior to the M501H, Mitsubishi introduced cooling-steam in “G series” gas turbines in 1997 to cool combustor liners. Recently, some of the advanced design technologies from the M501H gas turbine were applied to the G series gas turbine resulting in significant improvement in output and thermal efficiency. A noteworthy aspect of the technology transfer is that the upgraded G series M701G2 gas turbine has an almost equivalent output and thermal efficiency as H class gas turbines while continuing to rely on conventional air cooling of turbine blades and vanes, and time-proven materials from industrial gas turbine experience. In this paper we describe the key design features of the M701G2 gas turbine that make this possible such as the advanced 21:1 compressor with 14 stages, an advanced premix DLN combustor, etc., as well as shop load test results that were completed in 2002 at Mitsubishi’s in-house facility.
    keyword(s): Stress , Combustion chambers , Design , Gas turbines , Cooling , Turbines , Compressors , Blades , Rotors , Steam AND Pressure ,
    • Download: (751.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Application of “H Gas Turbine” Design Technology to Increase Thermal Efficiency and Output Capability of the Mitsubishi M701G2 Gas Turbine

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/131803
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorY. Fukuizumi
    contributor authorJ. Masada
    contributor authorY. Iwasaki
    contributor authorV. Kallianpur
    date accessioned2017-05-09T00:16:11Z
    date available2017-05-09T00:16:11Z
    date copyrightApril, 2005
    date issued2005
    identifier issn1528-8919
    identifier otherJETPEZ-26864#369_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/131803
    description abstractMitsubishi completed design development and verification load testing of a steam-cooled M501H gas turbine at a combined cycle power plant at Takasago, Japan in 2001. Several advanced technologies were specifically developed in addition to the steam-cooled components consisting of the combustor, turbine blades, vanes, and the rotor. Some of the other key technologies consisted of an advanced compressor with a pressure ratio of 25:1, active clearance control, and advanced seal technology. Prior to the M501H, Mitsubishi introduced cooling-steam in “G series” gas turbines in 1997 to cool combustor liners. Recently, some of the advanced design technologies from the M501H gas turbine were applied to the G series gas turbine resulting in significant improvement in output and thermal efficiency. A noteworthy aspect of the technology transfer is that the upgraded G series M701G2 gas turbine has an almost equivalent output and thermal efficiency as H class gas turbines while continuing to rely on conventional air cooling of turbine blades and vanes, and time-proven materials from industrial gas turbine experience. In this paper we describe the key design features of the M701G2 gas turbine that make this possible such as the advanced 21:1 compressor with 14 stages, an advanced premix DLN combustor, etc., as well as shop load test results that were completed in 2002 at Mitsubishi’s in-house facility.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleApplication of “H Gas Turbine” Design Technology to Increase Thermal Efficiency and Output Capability of the Mitsubishi M701G2 Gas Turbine
    typeJournal Paper
    journal volume127
    journal issue2
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.1850490
    journal fristpage369
    journal lastpage374
    identifier eissn0742-4795
    keywordsStress
    keywordsCombustion chambers
    keywordsDesign
    keywordsGas turbines
    keywordsCooling
    keywordsTurbines
    keywordsCompressors
    keywordsBlades
    keywordsRotors
    keywordsSteam AND Pressure
    treeJournal of Engineering for Gas Turbines and Power:;2005:;volume( 127 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian