    Euler Number Based Orifice Discharge Coefficient Relationship

    Source: Journal of Fluids Engineering:;2003:;volume( 125 ):;issue: 001::page 189
    Author:
    Gerald L. Morrison
    DOI: 10.1115/1.1521955
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A new relationship for orifice flow meter discharge coefficients has been developed which replaces the Reynolds number dependence with the Euler number. Both relationships have the same accuracy for the calculation of the discharge coefficient but the new relationship eliminates the need to know fluid viscosity.
    keyword(s): Discharge coefficient , Fluids , Reynolds number , Flow (Dynamics) , Flowmeters , Viscosity AND Pipes ,
    • Download: (225.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Euler Number Based Orifice Discharge Coefficient Relationship

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/128628
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorGerald L. Morrison
    date accessioned2017-05-09T00:10:38Z
    date available2017-05-09T00:10:38Z
    date copyrightJanuary, 2003
    date issued2003
    identifier issn0098-2202
    identifier otherJFEGA4-27181#189_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/128628
    description abstractA new relationship for orifice flow meter discharge coefficients has been developed which replaces the Reynolds number dependence with the Euler number. Both relationships have the same accuracy for the calculation of the discharge coefficient but the new relationship eliminates the need to know fluid viscosity.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEuler Number Based Orifice Discharge Coefficient Relationship
    typeJournal Paper
    journal volume125
    journal issue1
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.1521955
    journal fristpage189
    journal lastpage191
    identifier eissn1528-901X
    keywordsDischarge coefficient
    keywordsFluids
    keywordsReynolds number
    keywordsFlow (Dynamics)
    keywordsFlowmeters
    keywordsViscosity AND Pipes
    treeJournal of Fluids Engineering:;2003:;volume( 125 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian