    Von Karman Hydraulic Vortexes Cause Stay Vane Cracking on Propeller Turbines at the Little Long Generating Station of Ontario Hydro

    Source: Journal of Engineering for Gas Turbines and Power:;1968:;volume( 090 ):;issue: 003::page 213
    Author:
    E. Goldwag
    ,
    D. G. Berry
    DOI: 10.1115/1.3609174
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Little Long Generating Station is situated about 500 miles north of Toronto and is one of four plants located close together on the Mattagami River which flows into Hudson Bay. Some 500 MW of power is transmitted at 500 kv to Sudbury and Toronto (Fig. 1). There are two turbines at Little Long Generating Station. Almost immediately from the time when the first unit was being commissioned and operated under load, field reports referred to what was said to be an abnormally high level of noise and vibration. When the second unit came into service, similar findings were reported. About six months after commissioning, the units were unwatered and a detailed inspection indicated that the stay vanes forming the speed ring contained numerous and serious fatigue cracks. The final diagnosis indicated the damage to be a result of what is now usually referred to as von Karman hydraulic vortexes. Because immediate repairs were required and in order to insure the future structural adequacy of the speed ring, it was decided to change the stay vane profile at the same time, in an attempt to eliminate the excitation due to von Karman vortexes, hoping thereby to avoid further damage of the stay ring after the repairs. Recent inspections of both units show that both the modifications and the final repairs were completely successful.
    keyword(s): Fracture (Process) , Power stations , Turbines , Vortices , Propellers , Maintenance , Inspection , Flow (Dynamics) , Stress , Noise (Sound) , Vibration , Rivers , Fatigue cracks , Industrial plants AND Patient diagnosis ,
    • Download: (2.003Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Von Karman Hydraulic Vortexes Cause Stay Vane Cracking on Propeller Turbines at the Little Long Generating Station of Ontario Hydro

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/125822
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorE. Goldwag
    contributor authorD. G. Berry
    date accessioned2017-05-09T00:05:55Z
    date available2017-05-09T00:05:55Z
    date copyrightJuly, 1968
    date issued1968
    identifier issn1528-8919
    identifier otherJETPEZ-26670#213_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/125822
    description abstractLittle Long Generating Station is situated about 500 miles north of Toronto and is one of four plants located close together on the Mattagami River which flows into Hudson Bay. Some 500 MW of power is transmitted at 500 kv to Sudbury and Toronto (Fig. 1). There are two turbines at Little Long Generating Station. Almost immediately from the time when the first unit was being commissioned and operated under load, field reports referred to what was said to be an abnormally high level of noise and vibration. When the second unit came into service, similar findings were reported. About six months after commissioning, the units were unwatered and a detailed inspection indicated that the stay vanes forming the speed ring contained numerous and serious fatigue cracks. The final diagnosis indicated the damage to be a result of what is now usually referred to as von Karman hydraulic vortexes. Because immediate repairs were required and in order to insure the future structural adequacy of the speed ring, it was decided to change the stay vane profile at the same time, in an attempt to eliminate the excitation due to von Karman vortexes, hoping thereby to avoid further damage of the stay ring after the repairs. Recent inspections of both units show that both the modifications and the final repairs were completely successful.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleVon Karman Hydraulic Vortexes Cause Stay Vane Cracking on Propeller Turbines at the Little Long Generating Station of Ontario Hydro
    typeJournal Paper
    journal volume90
    journal issue3
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.3609174
    journal fristpage213
    journal lastpage217
    identifier eissn0742-4795
    keywordsFracture (Process)
    keywordsPower stations
    keywordsTurbines
    keywordsVortices
    keywordsPropellers
    keywordsMaintenance
    keywordsInspection
    keywordsFlow (Dynamics)
    keywordsStress
    keywordsNoise (Sound)
    keywordsVibration
    keywordsRivers
    keywordsFatigue cracks
    keywordsIndustrial plants AND Patient diagnosis
    treeJournal of Engineering for Gas Turbines and Power:;1968:;volume( 090 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian