    Shallow Flaws Under Biaxial Loading Conditions—Part I: The Effect of Specimen Size on Fracture Toughness Values Obtained From Large-Scale Cruciform Specimens1

    Source: Journal of Pressure Vessel Technology:;2001:;volume( 123 ):;issue: 001::page 10
    Author:
    Wallace J. McAfee
    ,
    B. Richard Bass
    ,
    Paul T. Williams
    DOI: 10.1115/1.1343910
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed. This technology is for application to the safety assessment of RPVs containing postulated shallow-surface flaws. It has been shown that relaxation of crack-tip constraint causes shallow-flaw fracture toughness of RPV material to have a higher mean value than that for deep flaws in the lower transition temperature region. Cruciform beam specimens developed at Oak Ridge National Laboratory (ORNL) introduce far-field, out-of-plane biaxial stress components in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock (PTS) loading of an RPV. The biaxial stress component has been shown to increase stress triaxiality (constraint) at the crack tip, and thereby reduce the shallow-flaw fracture toughness enhancement. The cruciform specimen permits controlled application of biaxial loading ratios, resulting in controlled variation of crack-tip constraint. An extensive matrix of intermediate-scale cruciform specimens with a uniform depth surface flaw was previously tested and demonstrated a continued decrease in shallow-flaw fracture toughness with increasing biaxial loading. This paper describes the test results for a series of large-scale cruciform specimens with a uniform depth surface flaw. These specimens were all of the same size with the same depth flaw and were tested at the same temperature and biaxial load ratio (1:1). The configuration is the same as the previous set of intermediate-scale tests, but has been scaled upward in size by 150 percent. These tests demonstrated the effect of biaxial loading and specimen size on shallow-flaw fracture toughness in the lower transition temperature region for RPV materials. For specimens tested under full biaxial (1:1) loading at test temperatures in the range of 23°F (−5°C) to 34°F (1°C), toughness was reduced by approximately 15 percent for a 150-percent increase in specimen size. This decrease was slightly greater than the predicted reduction for this increase in specimen size. The size corrections for 1/2T C(T) specimens did not predict the experimentally determined mean toughness values for larger size shallow-flaw specimens tested under biaxial (1:1) loading in the lower transition temperature region.
    keyword(s): Temperature , Stress , Fracture (Materials) , Fracture (Process) , Testing , Fracture toughness , Thickness , Toughness , Steel , Torque , Design AND Pressure vessels ,
    • Download: (1.381Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Shallow Flaws Under Biaxial Loading Conditions—Part I: The Effect of Specimen Size on Fracture Toughness Values Obtained From Large-Scale Cruciform Specimens1

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/125766
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorWallace J. McAfee
    contributor authorB. Richard Bass
    contributor authorPaul T. Williams
    date accessioned2017-05-09T00:05:49Z
    date available2017-05-09T00:05:49Z
    date copyrightFebruary, 2001
    date issued2001
    identifier issn0094-9930
    identifier otherJPVTAS-28407#10_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/125766
    description abstractA technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed. This technology is for application to the safety assessment of RPVs containing postulated shallow-surface flaws. It has been shown that relaxation of crack-tip constraint causes shallow-flaw fracture toughness of RPV material to have a higher mean value than that for deep flaws in the lower transition temperature region. Cruciform beam specimens developed at Oak Ridge National Laboratory (ORNL) introduce far-field, out-of-plane biaxial stress components in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock (PTS) loading of an RPV. The biaxial stress component has been shown to increase stress triaxiality (constraint) at the crack tip, and thereby reduce the shallow-flaw fracture toughness enhancement. The cruciform specimen permits controlled application of biaxial loading ratios, resulting in controlled variation of crack-tip constraint. An extensive matrix of intermediate-scale cruciform specimens with a uniform depth surface flaw was previously tested and demonstrated a continued decrease in shallow-flaw fracture toughness with increasing biaxial loading. This paper describes the test results for a series of large-scale cruciform specimens with a uniform depth surface flaw. These specimens were all of the same size with the same depth flaw and were tested at the same temperature and biaxial load ratio (1:1). The configuration is the same as the previous set of intermediate-scale tests, but has been scaled upward in size by 150 percent. These tests demonstrated the effect of biaxial loading and specimen size on shallow-flaw fracture toughness in the lower transition temperature region for RPV materials. For specimens tested under full biaxial (1:1) loading at test temperatures in the range of 23°F (−5°C) to 34°F (1°C), toughness was reduced by approximately 15 percent for a 150-percent increase in specimen size. This decrease was slightly greater than the predicted reduction for this increase in specimen size. The size corrections for 1/2T C(T) specimens did not predict the experimentally determined mean toughness values for larger size shallow-flaw specimens tested under biaxial (1:1) loading in the lower transition temperature region.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleShallow Flaws Under Biaxial Loading Conditions—Part I: The Effect of Specimen Size on Fracture Toughness Values Obtained From Large-Scale Cruciform Specimens1
    typeJournal Paper
    journal volume123
    journal issue1
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.1343910
    journal fristpage10
    journal lastpage24
    identifier eissn1528-8978
    keywordsTemperature
    keywordsStress
    keywordsFracture (Materials)
    keywordsFracture (Process)
    keywordsTesting
    keywordsFracture toughness
    keywordsThickness
    keywordsToughness
    keywordsSteel
    keywordsTorque
    keywordsDesign AND Pressure vessels
    treeJournal of Pressure Vessel Technology:;2001:;volume( 123 ):;issue: 001
    contenttypeFulltext