Acoustic Fatigue of a Steam Dump Pipe System Excited by Valve NoiseSource: Journal of Pressure Vessel Technology:;2001:;volume( 123 ):;issue: 004::page 461DOI: 10.1115/1.1400741Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The steam dump system in Gentilly Nuclear Power Plant consists of four parallel steam pipes, each of which comprises a steam control valve. Two pipes of this system experienced high-cycle fatigue damage. In-situ vibration and dynamic strain measurements were therefore conducted to identify the cause of the damage and formulate suitable counter-measures. The test results pointed to the high-frequency noise of the valve as the primary source causing the fatigue failure. By means of small-scale model tests, using a compressed air network, a new valve stem was developed, which produces a substantially lower noise level than that generated by the original valve stem. Implementing this new stem in the plant, without any other modifications in the valve body or the piping system, significantly reduced the dynamic stresses of the piping, but increased the vibration level of the valve itself. An alternative valve stem, which is a simpler version of the new design, was therefore tested and found to reduce the pipe stresses sufficiently while not increasing the level of valve vibration.
keyword(s): Fatigue , Noise (Sound) , Pipes , Valves , Acoustics , Steam AND Design ,
|
Collections
Show full item record
| contributor author | Suzanne Michaud | |
| contributor author | Samir Ziada | |
| contributor author | Henri Pastorel | |
| date accessioned | 2017-05-09T00:05:43Z | |
| date available | 2017-05-09T00:05:43Z | |
| date copyright | November, 2001 | |
| date issued | 2001 | |
| identifier issn | 0094-9930 | |
| identifier other | JPVTAS-28412#461_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/125709 | |
| description abstract | The steam dump system in Gentilly Nuclear Power Plant consists of four parallel steam pipes, each of which comprises a steam control valve. Two pipes of this system experienced high-cycle fatigue damage. In-situ vibration and dynamic strain measurements were therefore conducted to identify the cause of the damage and formulate suitable counter-measures. The test results pointed to the high-frequency noise of the valve as the primary source causing the fatigue failure. By means of small-scale model tests, using a compressed air network, a new valve stem was developed, which produces a substantially lower noise level than that generated by the original valve stem. Implementing this new stem in the plant, without any other modifications in the valve body or the piping system, significantly reduced the dynamic stresses of the piping, but increased the vibration level of the valve itself. An alternative valve stem, which is a simpler version of the new design, was therefore tested and found to reduce the pipe stresses sufficiently while not increasing the level of valve vibration. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Acoustic Fatigue of a Steam Dump Pipe System Excited by Valve Noise | |
| type | Journal Paper | |
| journal volume | 123 | |
| journal issue | 4 | |
| journal title | Journal of Pressure Vessel Technology | |
| identifier doi | 10.1115/1.1400741 | |
| journal fristpage | 461 | |
| journal lastpage | 468 | |
| identifier eissn | 1528-8978 | |
| keywords | Fatigue | |
| keywords | Noise (Sound) | |
| keywords | Pipes | |
| keywords | Valves | |
| keywords | Acoustics | |
| keywords | Steam AND Design | |
| tree | Journal of Pressure Vessel Technology:;2001:;volume( 123 ):;issue: 004 | |
| contenttype | Fulltext |