    Transition of Refrigeration Thermodynamic Analysis From Component to a Radar Power System

    Source: Journal of Energy Resources Technology:;2000:;volume( 122 ):;issue: 003::page 153
    Author:
    Mysore Ramalingam
    ,
    Brian Donovan
    ,
    Jerry E. Beam
    DOI: 10.1115/1.1289766
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Preliminary feasibility studies based on breakeven refrigeration thermodynamics, have been conducted for candidate power conditioning components in a transportable radar power system (Donovan, B.D. et al., 1995 “Effects of Refrigeration in a Transportable Cryogenic Aerospace Application,” Proc. 30th IECEC, Vol. 1, pp. 473–478; Ramalingam, M. et al., 1996 “Systems Analysis for a Cryogenic Aerospace Terrestrial Radar Power System,” Proc. 31st IECEC, Vol. 1). The analysis based on breakeven refrigeration thermodynamics revealed that in the case of a general switching device such as a power MOSFET, it would be more beneficial to operate it at 150 to 220 K, using a Stirling cycle-based cryocooler. The overall system efficiency was jeopardized by way of large input power requirements to cool small heat loads at lower temperatures, while the performance of the device itself suffered at higher temperatures. The break-even refrigeration thermodynamic analysis was also applied to multilayer ceramic capacitors at cryogenic temperatures. It was found that in order to avoid a power penalty for cooling the capacitor to 77 K, the cryocooled equivalent series resistance (ESR) value would have to be a factor of 40 lower than that of a conventional capacitor ESR value if using a Gifford-McMahon (GM) cooling cycle. A factor of 12 better improvement in ESR is required for a yet-to-be-developed more efficient Stirling cycle. In this paper, this break-even thermodynamic analytical concept was then partially extended from the component level to the radar power system level. The entire power system was sized based on several combinations of cryocooled generators, power conditioning, and antenna equipment. The analysis revealed that even though the radar output could potentially be increased two-to threefold by the introduction of cryocooled technologies, the sizes of the coolers begin to negate these advantages. Several power systems were evaluated with reference to a common figure-of-merit to arrive at an optimum configuration. [S0195-0738(00)00803-7]
    keyword(s): Temperature , Cooling , Power systems (Machinery) , Refrigeration , Radar , Power conditioning , Generators , Heat , Cycles AND Stress ,
    • Download: (366.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Transition of Refrigeration Thermodynamic Analysis From Component to a Radar Power System

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/123604
    Collections
    • Journal of Energy Resources Technology

    Show full item record

    contributor authorMysore Ramalingam
    contributor authorBrian Donovan
    contributor authorJerry E. Beam
    date accessioned2017-05-09T00:02:16Z
    date available2017-05-09T00:02:16Z
    date copyrightSeptember, 2000
    date issued2000
    identifier issn0195-0738
    identifier otherJERTD2-26491#153_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/123604
    description abstractPreliminary feasibility studies based on breakeven refrigeration thermodynamics, have been conducted for candidate power conditioning components in a transportable radar power system (Donovan, B.D. et al., 1995 “Effects of Refrigeration in a Transportable Cryogenic Aerospace Application,” Proc. 30th IECEC, Vol. 1, pp. 473–478; Ramalingam, M. et al., 1996 “Systems Analysis for a Cryogenic Aerospace Terrestrial Radar Power System,” Proc. 31st IECEC, Vol. 1). The analysis based on breakeven refrigeration thermodynamics revealed that in the case of a general switching device such as a power MOSFET, it would be more beneficial to operate it at 150 to 220 K, using a Stirling cycle-based cryocooler. The overall system efficiency was jeopardized by way of large input power requirements to cool small heat loads at lower temperatures, while the performance of the device itself suffered at higher temperatures. The break-even refrigeration thermodynamic analysis was also applied to multilayer ceramic capacitors at cryogenic temperatures. It was found that in order to avoid a power penalty for cooling the capacitor to 77 K, the cryocooled equivalent series resistance (ESR) value would have to be a factor of 40 lower than that of a conventional capacitor ESR value if using a Gifford-McMahon (GM) cooling cycle. A factor of 12 better improvement in ESR is required for a yet-to-be-developed more efficient Stirling cycle. In this paper, this break-even thermodynamic analytical concept was then partially extended from the component level to the radar power system level. The entire power system was sized based on several combinations of cryocooled generators, power conditioning, and antenna equipment. The analysis revealed that even though the radar output could potentially be increased two-to threefold by the introduction of cryocooled technologies, the sizes of the coolers begin to negate these advantages. Several power systems were evaluated with reference to a common figure-of-merit to arrive at an optimum configuration. [S0195-0738(00)00803-7]
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTransition of Refrigeration Thermodynamic Analysis From Component to a Radar Power System
    typeJournal Paper
    journal volume122
    journal issue3
    journal titleJournal of Energy Resources Technology
    identifier doi10.1115/1.1289766
    journal fristpage153
    journal lastpage160
    identifier eissn1528-8994
    keywordsTemperature
    keywordsCooling
    keywordsPower systems (Machinery)
    keywordsRefrigeration
    keywordsRadar
    keywordsPower conditioning
    keywordsGenerators
    keywordsHeat
    keywordsCycles AND Stress
    treeJournal of Energy Resources Technology:;2000:;volume( 122 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian