    Comparison of Flying-Hot-Wire and Stationary-Hot-Wire Measurements of Flow Over a Backward-Facing Step

    Source: Journal of Fluids Engineering:;1999:;volume( 121 ):;issue: 002::page 441
    Author:
    O. O. Badran
    ,
    H. H. Bruun
    DOI: 10.1115/1.2822229
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper is concerned with measurements of the flow field in the separated flow region behind a backward-facing step. The main instrument used in this research was Flying X Hot-Wire Anemometry (FHWA). Stationary (single normal) Hot-Wire Anemometry (SHWA) was also used. Comparative measurements between the SHW probe and the FHW system were conducted downstream of the step (step height H = 120 mm) and results are presented for axial locations of 1H and 2H. Two step configurations were considered; (i) a blunt leading edge with flow underneath (Case I) and (ii) a blunt leading edge with no flow underneath (Case II). It is observed from the results presented that the two Hot-Wire methods produce significantly different mean velocity and turbulence results inside the separation bubble. In particular, the SHWA method cannot detect the reverse flow velocity direction, while the Flying Hot-Wire clearly identifies the existing reverse flow. Also, in the shear flow region, the results presented indicate that measurements with a SHW probe must be treated with great caution.
    keyword(s): Flow (Dynamics) , Measurement , Wire , Foundry coatings , Probes , Shear flow , Bubbles , Instrumentation , Turbulence AND Separation (Technology) ,
    • Download: (523.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Comparison of Flying-Hot-Wire and Stationary-Hot-Wire Measurements of Flow Over a Backward-Facing Step

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/122377
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorO. O. Badran
    contributor authorH. H. Bruun
    date accessioned2017-05-09T00:00:05Z
    date available2017-05-09T00:00:05Z
    date copyrightJune, 1999
    date issued1999
    identifier issn0098-2202
    identifier otherJFEGA4-27140#441_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/122377
    description abstractThis paper is concerned with measurements of the flow field in the separated flow region behind a backward-facing step. The main instrument used in this research was Flying X Hot-Wire Anemometry (FHWA). Stationary (single normal) Hot-Wire Anemometry (SHWA) was also used. Comparative measurements between the SHW probe and the FHW system were conducted downstream of the step (step height H = 120 mm) and results are presented for axial locations of 1H and 2H. Two step configurations were considered; (i) a blunt leading edge with flow underneath (Case I) and (ii) a blunt leading edge with no flow underneath (Case II). It is observed from the results presented that the two Hot-Wire methods produce significantly different mean velocity and turbulence results inside the separation bubble. In particular, the SHWA method cannot detect the reverse flow velocity direction, while the Flying Hot-Wire clearly identifies the existing reverse flow. Also, in the shear flow region, the results presented indicate that measurements with a SHW probe must be treated with great caution.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparison of Flying-Hot-Wire and Stationary-Hot-Wire Measurements of Flow Over a Backward-Facing Step
    typeJournal Paper
    journal volume121
    journal issue2
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.2822229
    journal fristpage441
    journal lastpage445
    identifier eissn1528-901X
    keywordsFlow (Dynamics)
    keywordsMeasurement
    keywordsWire
    keywordsFoundry coatings
    keywordsProbes
    keywordsShear flow
    keywordsBubbles
    keywordsInstrumentation
    keywordsTurbulence AND Separation (Technology)
    treeJournal of Fluids Engineering:;1999:;volume( 121 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian