    Aspirating Probe Measurements of the Unsteady Total Temperature Field Downstream of an Embedded Stator in a Multistage Axial Flow Compressor

    Source: Journal of Turbomachinery:;1998:;volume( 120 ):;issue: 001::page 156
    Author:
    N. Suryavamshi
    ,
    B. Lakshminarayana
    ,
    J. Prato
    DOI: 10.1115/1.2841377
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The results from the area traverse measurements of the unsteady total temperature using a high-response aspirating probe downstream of the second stator of a three-stage axial flow compressor are presented. The measurements were conducted at the peak efficiency operating point. The unsteady total temperature data are resolved into deterministic and unresolved components. Hub and casing regions have high levels of unsteadiness and consequently high levels of mixing. These regions have significant levels of shaft resolved and unresolved unsteadiness. Comparisons are made between the total temperature and the total pressure data to examine the rotor 2 wake characteristics and the temporal variation of the stator exit flow. Isentropic efficiency calculations at the midpitch location show that there is about a 4 percent change in the algebraically averaged efficiency across the blades of the second rotor and if all the rotor 2 blades were behaving as a “best” blade, the improvement in efficiency would be about 1.3 percent. An attempt is made to create a composite flow field picture by correlating the unsteady velocity data with temperature and pressure data.
    • Download: (3.244Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Aspirating Probe Measurements of the Unsteady Total Temperature Field Downstream of an Embedded Stator in a Multistage Axial Flow Compressor

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/121366
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorN. Suryavamshi
    contributor authorB. Lakshminarayana
    contributor authorJ. Prato
    date accessioned2017-05-08T23:58:16Z
    date available2017-05-08T23:58:16Z
    date copyrightJanuary, 1998
    date issued1998
    identifier issn0889-504X
    identifier otherJOTUEI-28664#156_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/121366
    description abstractThe results from the area traverse measurements of the unsteady total temperature using a high-response aspirating probe downstream of the second stator of a three-stage axial flow compressor are presented. The measurements were conducted at the peak efficiency operating point. The unsteady total temperature data are resolved into deterministic and unresolved components. Hub and casing regions have high levels of unsteadiness and consequently high levels of mixing. These regions have significant levels of shaft resolved and unresolved unsteadiness. Comparisons are made between the total temperature and the total pressure data to examine the rotor 2 wake characteristics and the temporal variation of the stator exit flow. Isentropic efficiency calculations at the midpitch location show that there is about a 4 percent change in the algebraically averaged efficiency across the blades of the second rotor and if all the rotor 2 blades were behaving as a “best” blade, the improvement in efficiency would be about 1.3 percent. An attempt is made to create a composite flow field picture by correlating the unsteady velocity data with temperature and pressure data.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAspirating Probe Measurements of the Unsteady Total Temperature Field Downstream of an Embedded Stator in a Multistage Axial Flow Compressor
    typeJournal Paper
    journal volume120
    journal issue1
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.2841377
    journal fristpage156
    journal lastpage169
    identifier eissn1528-8900
    treeJournal of Turbomachinery:;1998:;volume( 120 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian