Flow-Induced Wear in Steam Generator Tubes—Prediction Versus Operational ExperienceSource: Journal of Pressure Vessel Technology:;1998:;volume( 120 ):;issue: 002::page 138Author:M. K. Au-Yang
DOI: 10.1115/1.2842231Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Many nuclear steam generators have accumulated more than 10 effective-full-power-years of operation. Eddy-current inspections revealed that a number of these steam generator tubes, notably those located in high local cross-flow regions, have indications of wear at some support plate elevations after 5 to 10 yr of effective-full-power operations. In the last 5 yr, a number of technical papers on nonlinear tube bundle dynamics has been published to address the effect of tube and support plate interactions. At the same time, test data relating wear and tube wall thickness losses for different material combinations and different support plate geometries became available. Based on the available data in the literature, as well as data obtained in the author’s affiliation, this paper assesses the cumulative tube wall wear after 5, 10, and 15 effective-full-power years of operation of a typical commercial nuclear steam generator, using different wear models. It is hoped that this study will shed some light on the probable mechanism that caused the observed wear in today’s operating nuclear steam generators.
keyword(s): Flow (Dynamics) , Wear , Boilers , Nuclear reactor steam generators , Wall thickness , Cross-flow , Mechanisms , Inspection , Eddy currents (Electricity) , Elevations (Drawings) AND Dynamics (Mechanics) ,
|
Collections
Show full item record
| contributor author | M. K. Au-Yang | |
| date accessioned | 2017-05-08T23:57:40Z | |
| date available | 2017-05-08T23:57:40Z | |
| date copyright | May, 1998 | |
| date issued | 1998 | |
| identifier issn | 0094-9930 | |
| identifier other | JPVTAS-28384#138_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/121030 | |
| description abstract | Many nuclear steam generators have accumulated more than 10 effective-full-power-years of operation. Eddy-current inspections revealed that a number of these steam generator tubes, notably those located in high local cross-flow regions, have indications of wear at some support plate elevations after 5 to 10 yr of effective-full-power operations. In the last 5 yr, a number of technical papers on nonlinear tube bundle dynamics has been published to address the effect of tube and support plate interactions. At the same time, test data relating wear and tube wall thickness losses for different material combinations and different support plate geometries became available. Based on the available data in the literature, as well as data obtained in the author’s affiliation, this paper assesses the cumulative tube wall wear after 5, 10, and 15 effective-full-power years of operation of a typical commercial nuclear steam generator, using different wear models. It is hoped that this study will shed some light on the probable mechanism that caused the observed wear in today’s operating nuclear steam generators. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Flow-Induced Wear in Steam Generator Tubes—Prediction Versus Operational Experience | |
| type | Journal Paper | |
| journal volume | 120 | |
| journal issue | 2 | |
| journal title | Journal of Pressure Vessel Technology | |
| identifier doi | 10.1115/1.2842231 | |
| journal fristpage | 138 | |
| journal lastpage | 143 | |
| identifier eissn | 1528-8978 | |
| keywords | Flow (Dynamics) | |
| keywords | Wear | |
| keywords | Boilers | |
| keywords | Nuclear reactor steam generators | |
| keywords | Wall thickness | |
| keywords | Cross-flow | |
| keywords | Mechanisms | |
| keywords | Inspection | |
| keywords | Eddy currents (Electricity) | |
| keywords | Elevations (Drawings) AND Dynamics (Mechanics) | |
| tree | Journal of Pressure Vessel Technology:;1998:;volume( 120 ):;issue: 002 | |
| contenttype | Fulltext |