    Flow Measurements in an Aortocoronary Bypass Graft Casting

    Source: Journal of Biomechanical Engineering:;1996:;volume( 118 ):;issue: 002::page 165
    Author:
    E. Y. Kwack
    ,
    X. M. Ruan
    ,
    A. Chaux
    ,
    L. H. Back
    DOI: 10.1115/1.2795955
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Flow visualization and pressure measurements were carried out in a single valve saphenous vein casting which was made from a saphenous vein segment obtained from a bypass patient at Cedars Sinai Medical Center. Dye was injected to understand the flow around the valve. The dye showed very complex flow patterns around the valve and in the valve sinus, and the cavity formed by a ligated branch. For steady flow, pressure drops across the valve were 0.72, 2.0 and 6.3 mmHg for the physiological flow rates of 45, 84, and 169 ml/min, respectively. Overall pressure drop across the casting (compared to Poiseuille flow for a straight tube) increased with the flow rate, being 130 to 290 percent higher over this flow rate range. In the case of pulsatile flow, pressure drops across the valve were 0.95 and 3.0 mmHg for the flow rates of 47 and 87 ml/min which were 26 and 43 percent higher than those of steady flow. Overall pressure drop was 220 and 360 percent higher for those flow rates compared to Poiseuille flow. The measured spatial pressure distributions along the casting and flow visualization indicated the global nature of the flow field with the accelerated flow through the valve separating and reattaching downstream along the wall in the pressure recovery region. Atherosclerosis may be prone to occur in the lower shear region along the wall beyond the valve tip in the reattachment region, as we have observed in vivo in rabbit experiments.
    keyword(s): Casting , Flow measurement , Flow (Dynamics) , Valves , Pressure drop , Poiseuille flow , Flow visualization , Pressure , Pressure measurement , Shear (Mechanics) , Cedar (Wood product) , Bifurcation , Cavities , Pulsatile flow , Physiology , Atherosclerosis AND Biomedicine ,
    • Download: (893.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Flow Measurements in an Aortocoronary Bypass Graft Casting

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/116579
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorE. Y. Kwack
    contributor authorX. M. Ruan
    contributor authorA. Chaux
    contributor authorL. H. Back
    date accessioned2017-05-08T23:49:27Z
    date available2017-05-08T23:49:27Z
    date copyrightMay, 1996
    date issued1996
    identifier issn0148-0731
    identifier otherJBENDY-25962#165_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/116579
    description abstractFlow visualization and pressure measurements were carried out in a single valve saphenous vein casting which was made from a saphenous vein segment obtained from a bypass patient at Cedars Sinai Medical Center. Dye was injected to understand the flow around the valve. The dye showed very complex flow patterns around the valve and in the valve sinus, and the cavity formed by a ligated branch. For steady flow, pressure drops across the valve were 0.72, 2.0 and 6.3 mmHg for the physiological flow rates of 45, 84, and 169 ml/min, respectively. Overall pressure drop across the casting (compared to Poiseuille flow for a straight tube) increased with the flow rate, being 130 to 290 percent higher over this flow rate range. In the case of pulsatile flow, pressure drops across the valve were 0.95 and 3.0 mmHg for the flow rates of 47 and 87 ml/min which were 26 and 43 percent higher than those of steady flow. Overall pressure drop was 220 and 360 percent higher for those flow rates compared to Poiseuille flow. The measured spatial pressure distributions along the casting and flow visualization indicated the global nature of the flow field with the accelerated flow through the valve separating and reattaching downstream along the wall in the pressure recovery region. Atherosclerosis may be prone to occur in the lower shear region along the wall beyond the valve tip in the reattachment region, as we have observed in vivo in rabbit experiments.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleFlow Measurements in an Aortocoronary Bypass Graft Casting
    typeJournal Paper
    journal volume118
    journal issue2
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2795955
    journal fristpage165
    journal lastpage171
    identifier eissn1528-8951
    keywordsCasting
    keywordsFlow measurement
    keywordsFlow (Dynamics)
    keywordsValves
    keywordsPressure drop
    keywordsPoiseuille flow
    keywordsFlow visualization
    keywordsPressure
    keywordsPressure measurement
    keywordsShear (Mechanics)
    keywordsCedar (Wood product)
    keywordsBifurcation
    keywordsCavities
    keywordsPulsatile flow
    keywordsPhysiology
    keywordsAtherosclerosis AND Biomedicine
    treeJournal of Biomechanical Engineering:;1996:;volume( 118 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian