    Archive

    The Simulation of Discrete Vessel Effects in Experimental Hyperthermia

    Source: Journal of Biomechanical Engineering:;1994:;volume( 116 ):;issue: 003::page 256
    Author:
    R. J. Rawnsley
    ,
    R. B. Roemer
    ,
    A. W. Dutton
    DOI: 10.1115/1.2895728
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The ability of two simple thermal models to predict experimentally measured in vivo temperature profiles was compared. These comparisons were done both with and without the inclusion of separate, discrete blood vessels. The two tissue models were: 1) Pennes’ Bio-Heat Transfer equation (BHTE), and 2) an effective thermal conductivity equation (ETCE). The experimental temperature data were measured (Moros, 1990; Moros et al., 1993) in the thighs of anesthetized greyhound dogs under hyperthermic conditions generated by scanned focused ultrasound. Blood vessels were added to the thermal models in counter-current pairs transiting the model domain. The blood vessels in both models were assumed to have a constant heat transfer coefficient, and an axially varying mixed mean temperature. The vessel locations were determined a posteriori, via inspection of the experimental temperature data. Least square error fits of the predicted model temperatures to the experimental temperature data were obtained by adjusting both (a) the mass flow rate within and (b) the position of each blood vessel, and (c) the value of either the perfusion parameter (W) in the BHTE or the effective thermal conductivity parameter (Keff ) in the ETCE. When small numbers (3-4) of blood vessel pairs were included, both of the models showed significant improvement in their ability to predict the experimental temperatures. Although both models performed well in terms of predicting temperatures near large vessels, the BHTE had a statistically significant better ability to predict the complete set of measured temperatures at all locations.
    keyword(s): Simulation , Vessels , Temperature , Blood vessels , Equations , Thermal conductivity , Bioheat transfer , Biological tissues , Heat transfer coefficients , Flow (Dynamics) , Errors , Temperature profiles , Inspection AND Ultrasound ,
    • Download: (1.111Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      The Simulation of Discrete Vessel Effects in Experimental Hyperthermia

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/113235
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorR. J. Rawnsley
    contributor authorR. B. Roemer
    contributor authorA. W. Dutton
    date accessioned2017-05-08T23:43:36Z
    date available2017-05-08T23:43:36Z
    date copyrightAugust, 1994
    date issued1994
    identifier issn0148-0731
    identifier otherJBENDY-25941#256_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/113235
    description abstractThe ability of two simple thermal models to predict experimentally measured in vivo temperature profiles was compared. These comparisons were done both with and without the inclusion of separate, discrete blood vessels. The two tissue models were: 1) Pennes’ Bio-Heat Transfer equation (BHTE), and 2) an effective thermal conductivity equation (ETCE). The experimental temperature data were measured (Moros, 1990; Moros et al., 1993) in the thighs of anesthetized greyhound dogs under hyperthermic conditions generated by scanned focused ultrasound. Blood vessels were added to the thermal models in counter-current pairs transiting the model domain. The blood vessels in both models were assumed to have a constant heat transfer coefficient, and an axially varying mixed mean temperature. The vessel locations were determined a posteriori, via inspection of the experimental temperature data. Least square error fits of the predicted model temperatures to the experimental temperature data were obtained by adjusting both (a) the mass flow rate within and (b) the position of each blood vessel, and (c) the value of either the perfusion parameter (W) in the BHTE or the effective thermal conductivity parameter (Keff ) in the ETCE. When small numbers (3-4) of blood vessel pairs were included, both of the models showed significant improvement in their ability to predict the experimental temperatures. Although both models performed well in terms of predicting temperatures near large vessels, the BHTE had a statistically significant better ability to predict the complete set of measured temperatures at all locations.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Simulation of Discrete Vessel Effects in Experimental Hyperthermia
    typeJournal Paper
    journal volume116
    journal issue3
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2895728
    journal fristpage256
    journal lastpage262
    identifier eissn1528-8951
    keywordsSimulation
    keywordsVessels
    keywordsTemperature
    keywordsBlood vessels
    keywordsEquations
    keywordsThermal conductivity
    keywordsBioheat transfer
    keywordsBiological tissues
    keywordsHeat transfer coefficients
    keywordsFlow (Dynamics)
    keywordsErrors
    keywordsTemperature profiles
    keywordsInspection AND Ultrasound
    treeJournal of Biomechanical Engineering:;1994:;volume( 116 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian