    Wind Evaporator Heat Pumps—Part II: Thermal Performance Results

    Source: Journal of Energy Resources Technology:;1992:;volume( 114 ):;issue: 004::page 286
    Author:
    J. M. O’Reilly
    ,
    P. F. Monaghan
    DOI: 10.1115/1.2905955
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Wind evaporators are alternative evaporators for air source heat pumps which rely on wind-driven or natural convection to move air across the heat transfer surfaces. A fully automatic, computer-controlled test facility which allows side-by-side testing of wind evaporator and conventional heat pumps and monitoring of weather conditions has been designed and built at University College Galway. The aim of this paper is to quantify the advantages of wind evaporators by comparing the performance of a wind evaporator heat pump with that of a conventional heat pump over an extended testing period and by examining the relationship between weather conditions and heat pump performance. In this paper, results are presented in the form of plots of coefficient of performance (COP), compressor power, evaporator and condenser heat transfers and climatic variables against time. In addition, a testing period coefficient of performance has been calculated for each heat pump. The results show that wind speed is the dominant climatic variable affecting wind evaporator heat pump performance, and that frost growth does not significantly reduce this performance. Even at extremely low wind speeds, the COP of the wind evaporator heat pump is not significantly affected. After over 460 hr of testing, the testing period COP of the wind evaporator heat pump shows a 16 percent increase over that of the conventional heat pump. (Refer to Nomenclature in Part I of this paper.)
    keyword(s): Heat pumps , Wind , Testing , Heat transfer , Wind velocity , Natural convection , Compressors , Computers , Condensers (steam plant) AND Test facilities ,
    • Download: (337.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Wind Evaporator Heat Pumps—Part II: Thermal Performance Results

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/110109
    Collections
    • Journal of Energy Resources Technology

    Show full item record

    contributor authorJ. M. O’Reilly
    contributor authorP. F. Monaghan
    date accessioned2017-05-08T23:38:11Z
    date available2017-05-08T23:38:11Z
    date copyrightDecember, 1992
    date issued1992
    identifier issn0195-0738
    identifier otherJERTD2-26447#286_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/110109
    description abstractWind evaporators are alternative evaporators for air source heat pumps which rely on wind-driven or natural convection to move air across the heat transfer surfaces. A fully automatic, computer-controlled test facility which allows side-by-side testing of wind evaporator and conventional heat pumps and monitoring of weather conditions has been designed and built at University College Galway. The aim of this paper is to quantify the advantages of wind evaporators by comparing the performance of a wind evaporator heat pump with that of a conventional heat pump over an extended testing period and by examining the relationship between weather conditions and heat pump performance. In this paper, results are presented in the form of plots of coefficient of performance (COP), compressor power, evaporator and condenser heat transfers and climatic variables against time. In addition, a testing period coefficient of performance has been calculated for each heat pump. The results show that wind speed is the dominant climatic variable affecting wind evaporator heat pump performance, and that frost growth does not significantly reduce this performance. Even at extremely low wind speeds, the COP of the wind evaporator heat pump is not significantly affected. After over 460 hr of testing, the testing period COP of the wind evaporator heat pump shows a 16 percent increase over that of the conventional heat pump. (Refer to Nomenclature in Part I of this paper.)
    publisherThe American Society of Mechanical Engineers (ASME)
    titleWind Evaporator Heat Pumps—Part II: Thermal Performance Results
    typeJournal Paper
    journal volume114
    journal issue4
    journal titleJournal of Energy Resources Technology
    identifier doi10.1115/1.2905955
    journal fristpage286
    journal lastpage290
    identifier eissn1528-8994
    keywordsHeat pumps
    keywordsWind
    keywordsTesting
    keywordsHeat transfer
    keywordsWind velocity
    keywordsNatural convection
    keywordsCompressors
    keywordsComputers
    keywordsCondensers (steam plant) AND Test facilities
    treeJournal of Energy Resources Technology:;1992:;volume( 114 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian