    Analytical Reconstruction of the Running Surfaces of Gear Teeth. Part 2: Combining Tooth Spacing Measurements with Profile and Lead Measurements

    Source: Journal of Mechanical Design:;1987:;volume( 109 ):;issue: 002::page 268
    Author:
    W. D. Mark
    DOI: 10.1115/1.3267450
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Methods are developed for analytically reconstructing the absolute geometric deviations of the running surfaces of all teeth on a gear or pinion from perfect equispaced involute surfaces. Two of the methods utilize a rectangular array of tooth spacing deviation point measurements optimally located at the zeros of Legendre polynomials in the axial and radial directions where profile and lead deviation measurements are assumed to have been made. Each of these two methods utilizes the multiple tooth spacing deviation measurements to determine the absolute spacing deviations of the mean planes of the deviations of the tooth running surfaces determined from profile and lead measurements. A convergent two-dimensional Legendre polynomial representation of tooth surface deviations that interpolates between point measurements of tooth surface deviations located in rectangular arrays at the aforementioned zeros of Legendre polynomials is described. A discussion of the general relationships between adjacent and accumulated tooth spacing deviations is provided. The noninsignificant measurement errors that typically arise in profile, lead, and tooth spacing deviation measurements are taken into account at each step in the work.
    keyword(s): Measurement , Gear teeth , Polynomials , Gears AND Errors ,
    • Download: (850.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Analytical Reconstruction of the Running Surfaces of Gear Teeth. Part 2: Combining Tooth Spacing Measurements with Profile and Lead Measurements

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/102772
    Collections
    • Journal of Mechanical Design

    Show full item record

    contributor authorW. D. Mark
    date accessioned2017-05-08T23:25:19Z
    date available2017-05-08T23:25:19Z
    date copyrightJune, 1987
    date issued1987
    identifier issn1050-0472
    identifier otherJMDEDB-28077#268_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/102772
    description abstractMethods are developed for analytically reconstructing the absolute geometric deviations of the running surfaces of all teeth on a gear or pinion from perfect equispaced involute surfaces. Two of the methods utilize a rectangular array of tooth spacing deviation point measurements optimally located at the zeros of Legendre polynomials in the axial and radial directions where profile and lead deviation measurements are assumed to have been made. Each of these two methods utilizes the multiple tooth spacing deviation measurements to determine the absolute spacing deviations of the mean planes of the deviations of the tooth running surfaces determined from profile and lead measurements. A convergent two-dimensional Legendre polynomial representation of tooth surface deviations that interpolates between point measurements of tooth surface deviations located in rectangular arrays at the aforementioned zeros of Legendre polynomials is described. A discussion of the general relationships between adjacent and accumulated tooth spacing deviations is provided. The noninsignificant measurement errors that typically arise in profile, lead, and tooth spacing deviation measurements are taken into account at each step in the work.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAnalytical Reconstruction of the Running Surfaces of Gear Teeth. Part 2: Combining Tooth Spacing Measurements with Profile and Lead Measurements
    typeJournal Paper
    journal volume109
    journal issue2
    journal titleJournal of Mechanical Design
    identifier doi10.1115/1.3267450
    journal fristpage268
    journal lastpage274
    identifier eissn1528-9001
    keywordsMeasurement
    keywordsGear teeth
    keywordsPolynomials
    keywordsGears AND Errors
    treeJournal of Mechanical Design:;1987:;volume( 109 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian