Show simple item record

dc.contributor.authorT. Okada
dc.contributor.authorS. Hattori
dc.date.accessioned2017-05-08T23:20:24Z
dc.date.available2017-05-08T23:20:24Z
dc.date.copyrightJuly, 1985
dc.date.issued1985
dc.identifier.issn0094-4289
dc.identifier.otherJEMTA8-26906#235_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/99932
dc.description.abstractThe corrosion fatigue properties of 0.37 percent carbon structural steel (AISI 1035) were studied in salt water having concentrations from 0 wt percent (ion exchanged water) to 10 wt percent. The fatigue strength (at 107 cycles) decreased linearly with logarithmic increase in concentration between 0.005 wt and 3 wt percent. The reduction in fatigue strength is possibly due to a wide separation of individual corroded areas by the high electrical conductivity of salt water. The fatigue strength in low concentration salt water (less than 0.005 wt percent) is almost the same as that in ion exchanged water. This may be because, in water of poor conductivity, a large number of small cracks were initiated and some of them were joined with each other.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleRelation Between Concentration of Salt Water and Corrosion Fatigue Strength on 0.37 Percent Carbon Structural Steel
dc.typeJournal Paper
dc.journal.volume107
dc.journal.issue3
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.3225809
dc.journal.fristpage235
dc.journal.lastpage239
dc.identifier.eissn1528-8889
dc.keywordsStructural steel
dc.keywordsCarbon
dc.keywordsCorrosion
dc.keywordsFatigue strength
dc.keywordsWater
dc.keywordsFatigue properties
dc.keywordsConductivity
dc.keywordsCycles
dc.keywordsFracture (Materials)
dc.keywordsElectrical conductivity AND Separation (Technology)
dc.treeJournal of Engineering Materials and Technology:;1985:;volume( 107 ):;issue: 003