Show simple item record

dc.contributor.authorM. Raoof
dc.contributor.authorR. E. Hobbs
dc.date.accessioned2017-05-08T23:17:33Z
dc.date.available2017-05-08T23:17:33Z
dc.date.copyrightSeptember, 1984
dc.date.issued1984
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26400#349_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/98292
dc.description.abstractThe problem of the bending of a spiral strand or armored cable is addressed, with particular reference to the “free bending” situation where pulleys or other restraints are absent. The analysis, based on a study of the properties of the layers of wires which form the strand (or armor), treats the “free field” bending, remote from the termination. A parallel treatment of the situation close to a termination is summarized. In the former case, limiting values for the effective bending stiffness of the strand are presented; in the latter case an examination of the behavior of an outer layer of wires sliding (with known frictional characteristics) over an inner core has led to predictions of the strains and movements between the individual wires and the inner core (as a function of wire position in the strand) which are reported in the paper. The results offer an explanation of some experimental observations from fatigue tests on a large (39mm) strand under combined steady axial load and lateral movements causing bending adjacent to the restrained termination. In particular the observed wire failures close to the socket, not at the extreme fiber positions but at the neutral axis, can be explained in terms of the much larger slip on the interlayer contact points there.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThe Bending of Spiral Strand and Armored Cables Close to Terminations
dc.typeJournal Paper
dc.journal.volume106
dc.journal.issue3
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3231064
dc.journal.fristpage349
dc.journal.lastpage355
dc.identifier.eissn1528-8994
dc.keywordsCables
dc.keywordsWire
dc.keywordsMotion
dc.keywordsFibers
dc.keywordsStress
dc.keywordsFailure
dc.keywordsFatigue testing
dc.keywordsPulleys
dc.keywordsStiffness AND Armor
dc.treeJournal of Energy Resources Technology:;1984:;volume( 106 ):;issue: 003