dc.description.abstractA simplified formula for predicting the change in bolt load from preload to operating condition in a ring-type bolted flange connection is presented. The results clearly demonstrate the important dimensionless parameters that affect the magnitude and direction of the bolt load change.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDesign Parameters Affecting Bolt Load in Ring-Type Gasketed Joints