Show simple item record

dc.contributor.authorP. H. Thornton
dc.date.accessioned2017-05-08T23:15:40Z
dc.date.available2017-05-08T23:15:40Z
dc.date.copyrightJuly, 1983
dc.date.issued1983
dc.identifier.issn0094-4289
dc.identifier.otherJEMTA8-26893#173_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/97173
dc.description.abstractThe initial collapse load and the energy absorbed during collapse were measured for brass tubing over a range of compression rates from ∼ 2 × 10−4 m/s to ∼ 12 m/s using two different load cells. Large differences in the initial collapse load under quasi-static loading could be produced by different trigger mechanisms. These differences were reduced as the compression rate was increased. Load cell inertia effects could cause the true form of the load/compression curve to be obscured. Although such ringing responses precluded accurate measurements of the initial collapse load, the measured energy absorbed during the collapse was not affected.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDynamic Crush of Tubes
dc.typeJournal Paper
dc.journal.volume105
dc.journal.issue3
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.3225638
dc.journal.fristpage173
dc.journal.lastpage175
dc.identifier.eissn1528-8889
dc.keywordsInertia (Mechanics)
dc.keywordsBrass (Metal)
dc.keywordsMeasurement
dc.keywordsStress
dc.keywordsTubing
dc.keywordsCollapse
dc.keywordsCompression AND Mechanisms
dc.treeJournal of Engineering Materials and Technology:;1983:;volume( 105 ):;issue: 003