Show simple item record

dc.contributor.authorR. S. Hecklinger
dc.contributor.authorL. M. Grillo
dc.date.accessioned2017-05-08T23:15:19Z
dc.date.available2017-05-08T23:15:19Z
dc.date.copyrightJune, 1983
dc.date.issued1983
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26390#255_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/96977
dc.description.abstractDetermination of thermal performance or efficiency of steam generators by traditional ASME procedures is a complex and difficult undertaking. When the fuel is municipal solid waste, additional variables are introduced to confound the procedures further. A new approach is proposed as a basis for discussion. The intent of the new approach is to reduce the time and effort required to achieve agreement that a municipal-solid-waste-fired steam generator has performed as specified and/or guaranteed.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermal Performance Evaluation of MSW-Fired Steam Generators—A New Approach
dc.typeJournal Paper
dc.journal.volume105
dc.journal.issue2
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3230911
dc.journal.fristpage255
dc.journal.lastpage257
dc.identifier.eissn1528-8994
dc.keywordsMunicipal solid wastes
dc.keywordsBoilers
dc.keywordsPerformance evaluation AND Fuels
dc.treeJournal of Energy Resources Technology:;1983:;volume( 105 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record