dc.description.abstractCollapse testing of commercial API grade 7-in. casing was conducted under combined external pressure and axial load. The measured collapse pressure was considerably higher than the API minimum value, especially for the large D/t ratio, as expected. For the casings of large D/t ratio, the measured collapse pressure was a little smaller than the theoretical value for ideal pipe and the axial stress had a slight effect on the collapse pressure. In the range of plastic collapse, the measured collapse pressure was not less than the yield pressure for ideal pipe except near the boundary of the elastic and plastic collapse ranges.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleExamination of Commercial Casing Collapse Strength Under Axial Loading
dc.typeJournal Paper
dc.journal.volume104
dc.journal.issue4
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3230426
dc.journal.fristpage343
dc.journal.lastpage348
dc.identifier.eissn1528-8994
dc.keywordsCollapse
dc.keywordsPressure
dc.keywordsStress
dc.keywordsPipes
dc.keywordsAmerican Petroleum Institute
dc.keywordsExternal pressure AND Testing
dc.treeJournal of Energy Resources Technology:;1982:;volume( 104 ):;issue: 004