    Creep Rupture Bending Test of 20 Percent Cold-Prestrained Ni-Fe-Cr Alloy Straight Tubes at 1100 F(593 C)

    Thumbnail
    View/Open
    JPVTAS-28204#337_1.pdf (1.994Mb)
    Date
    1981
    Author
    H. H. Woo
    R. H. Ryder
    K. H. Holko
    R. F. Stetson
    Metadata
    Show full item record
    Abstract
    A four-point bend test was performed on 20 percent cold-prestrained Ni-Fe-Cr alloy tubes at 1100 F (593 C) to verify that creep rupture damage can be used to predict failure in a nonuniform stress field. Deflection control and acoustic emission techniques were used to detect crack initiation, strain gages were employed to record the strain history in the specimen, and a scanning electron microscrope was utilized to check crack initiation and propagation. Stress analyses were made using simplified and finite element methods. Comparison of test results and analyses concluded that creep rupture damage can be used to predict local material failure for structural components under multiaxial nonuniform loading conditions.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/95008
    Collections
    • Journal of Pressure Vessel Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV