| dc.contributor.author | J. P. Thornton | |
| dc.contributor.author | D. Waddington | |
| dc.date.accessioned | 2017-05-08T23:09:54Z | |
| dc.date.available | 2017-05-08T23:09:54Z | |
| dc.date.copyright | February, 1980 | |
| dc.date.issued | 1980 | |
| dc.identifier.issn | 0199-6231 | |
| dc.identifier.other | JSEEDO-28128#22_1.pdf | |
| dc.identifier.uri | http://yetl.yabesh.ir/yetl/handle/yetl/93870 | |
| dc.description.abstract | A key milestone in the development of any solar collector is the comparison of actual performance data with predicted data. During a series of tests at the Martin Marietta solar test facility during 1976 and 1977, the performance of four full-size, prototype heliostats with different types and sizes of glass mirrors were measured and subseqeuently shown to compare closely with the predicted performances. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | Measurement of Heliostat Performance Characteristics | |
| dc.type | Journal Paper | |
| dc.journal.volume | 102 | |
| dc.journal.issue | 1 | |
| dc.journal.title | Journal of Solar Energy Engineering | |
| dc.identifier.doi | 10.1115/1.3266117 | |
| dc.journal.fristpage | 22 | |
| dc.journal.lastpage | 33 | |
| dc.identifier.eissn | 1528-8986 | |
| dc.keywords | Glass | |
| dc.keywords | Engineering prototypes | |
| dc.keywords | Solar collectors | |
| dc.keywords | Solar energy | |
| dc.keywords | Mirrors | |
| dc.keywords | Test facilities AND Performance characterization | |
| dc.tree | Journal of Solar Energy Engineering:;1980:;volume( 102 ):;issue: 001 | |
| dc.contenttype | Fulltext | |