    A Fracture Surface Rotation Mechanism for Fatigue Tested 2219-T87 Aluminum Sheet

    Thumbnail
    View/Open
    JEMTA8-26867#80_1.pdf (1.467Mb)
    Date
    1979
    Author
    G. F. Pittinato
    Metadata
    Show full item record
    Abstract
    Fatigue crack propagation tests were conducted on 2219-T87 aluminum sheet to identify the factors that control the rate of fracture surface rotation. Center-cracked, axial loaded specimens were tested in air at room temperature using tension-tension loading. The log (da/dn) versus (ΔK) curve contained an inflection point that was associated with the flat to slant fracture transition. The size and shape of the plastic zone at the crack tip were determined as a function of the half-crack length by using optical interferometry. It was found that the rate of fracture surface rotation was controlled by the changing size of the crack tip plastic zone. It is proposed that fracture surface rotation in this material occurs by a process of crack movement within active slip zones. A discussion is given on the deformation mechanisms associated with fatigue fracture surface rotation.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/92242
    Collections
    • Journal of Engineering Materials and Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV