Show simple item record

dc.contributor.authorHan C. Wu
dc.contributor.authorD. R. Rummler
dc.date.accessioned2017-05-08T23:06:55Z
dc.date.available2017-05-08T23:06:55Z
dc.date.copyrightJanuary, 1979
dc.date.issued1979
dc.identifier.issn0094-4289
dc.identifier.otherJEMTA8-26867#68_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/92240
dc.description.abstractMany experimenters fail to appreciate the significance of test system alignment during a tensile test. Poor alignment can increase data scatter and significantly influence some of the test results. In this paper a comprehensive analytical study of the misalignment problem in the plastic strain range is presented and errors caused by misalignment estimated. The results show that the stress-strain curve is not significantly affected by misalignment. However, the strains at the outer most fibers of the specimen cross-section are stongly affected by misalignment. Therefore, the effect of misalignment is most important when properties sensitive to local strain concentrations are being investigated.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalysis of Misalignment in the Tension Test
dc.typeJournal Paper
dc.journal.volume101
dc.journal.issue1
dc.journal.titleJournal of Engineering Materials and Technology
dc.identifier.doi10.1115/1.3443653
dc.journal.fristpage68
dc.journal.lastpage74
dc.identifier.eissn1528-8889
dc.keywordsFibers
dc.keywordsStress-strain curves
dc.keywordsElectromagnetic scattering
dc.keywordsErrors AND Tension
dc.treeJournal of Engineering Materials and Technology:;1979:;volume( 101 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record