Show simple item record

dc.contributor.authorS. W. Pearson
dc.date.accessioned2017-05-08T23:06:29Z
dc.date.available2017-05-08T23:06:29Z
dc.date.copyrightDecember, 1979
dc.date.issued1979
dc.identifier.issn0195-0738
dc.identifier.otherJERTD2-26376#225_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/92009
dc.description.abstractExtensive soil temperature measurements have been taken for more than two years in a field test designed to monitor the performance of thermal vertical support members used to support elevated sections of the trans-Alaska pipeline as it crosses marginal permafrost. Thermal aspects of the design are summarized and soil temperature data are presented which demonstrate the ability of the overall thermal vertical support member system to protect the surrounding permafrost.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermal Performance Verification of Thermal Vertical Support Members for the Trans-Alaska Pipeline
dc.typeJournal Paper
dc.journal.volume101
dc.journal.issue4
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.3446924
dc.journal.fristpage225
dc.journal.lastpage231
dc.identifier.eissn1528-8994
dc.keywordsPipelines
dc.keywordsSoil
dc.keywordsTemperature
dc.keywordsTemperature measurement AND Design
dc.treeJournal of Energy Resources Technology:;1979:;volume( 101 ):;issue: 004
dc.contenttypeFulltext