Show simple item record

dc.contributor.authorH. I. Epstein
dc.contributor.authorJ. R. Buzek
dc.date.accessioned2017-05-08T23:05:36Z
dc.date.available2017-05-08T23:05:36Z
dc.date.copyrightAugust, 1978
dc.date.issued1978
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28165#291_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/91481
dc.description.abstractProcedures are developed for determining the stresses and displacements for pontoon-type floating roof structures subjected to the loading caused by the product leaking through punctures onto the deck. The effects of various parameters such as tank diameter, product density and pontoon geometry are examined. Numerical examples are presented which compare the stresses and deflections for the ruptured case to those caused by accumulated rainwater. Large axial compressive stresses together with their associated buckling problems are found in the pontoon for the examples presented. Possible corrective measures for these problems are considered.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleStresses in Ruptured Floating Roofs
dc.typeJournal Paper
dc.journal.volume100
dc.journal.issue3
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3454469
dc.journal.fristpage291
dc.journal.lastpage296
dc.identifier.eissn1528-8978
dc.keywordsStress
dc.keywordsRoofs
dc.keywordsLeakage
dc.keywordsDensity
dc.keywordsBuckling
dc.keywordsCompressive stress
dc.keywordsDeflection AND Geometry
dc.treeJournal of Pressure Vessel Technology:;1978:;volume( 100 ):;issue: 003