Show simple item record

dc.contributor.authorM. Reich
dc.contributor.authorT. Y. Chang
dc.contributor.authorS. Prachuktam
dc.date.accessioned2017-05-08T23:05:34Z
dc.date.available2017-05-08T23:05:34Z
dc.date.copyrightNovember, 1978
dc.date.issued1978
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28167#354_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/91462
dc.description.abstractThe occurrence of PWR steam generator tube cracking, denting, and wastage has been reported in the recent literature [1–5]. As indicated by its title, this paper concerns itself with the inelastic structural response of the tubes that result from various assumed monotonic as well as cyclic loading conditions, which ultimately could lead to the tube failure.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleFailure Analysis of Steam Generator Tubes With Dented and Wastage Configurations
dc.typeJournal Paper
dc.journal.volume100
dc.journal.issue4
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3454481
dc.journal.fristpage354
dc.journal.lastpage359
dc.identifier.eissn1528-8978
dc.keywordsBoilers
dc.keywordsFailure analysis
dc.keywordsPressurized water reactors
dc.keywordsFracture (Process) AND Failure
dc.treeJournal of Pressure Vessel Technology:;1978:;volume( 100 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record