Show simple item record

dc.contributor.authorC. E. Murphey
dc.date.accessioned2017-05-08T23:03:46Z
dc.date.available2017-05-08T23:03:46Z
dc.date.copyrightFebruary, 1977
dc.date.issued1977
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28141#208_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/90418
dc.description.abstractCollapse tests were performed on one-in. dia steel tubes with flats milled on the exterior to simulate worn casing. External pressure and axial load were applied to the tubs having a range of wall thickness, yield strength, and degree of wear. Empirical correlation of the data and comparison with elastic collapse calculations indicate the percentage reduction in collapse pressure due to wear. This reduction is predictable within upper and lower bounds. While the milled external flat may not accurately simulate severe internal wear, the correlation is adequate for less than severe wear to give an indication of remaining strength.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleCollapse of Worn Casing
dc.typeJournal Paper
dc.journal.volume99
dc.journal.issue1
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3454511
dc.journal.fristpage208
dc.journal.lastpage214
dc.identifier.eissn1528-8978
dc.keywordsCollapse
dc.keywordsWear
dc.keywordsSteel
dc.keywordsStress
dc.keywordsPressure
dc.keywordsExternal pressure
dc.keywordsWall thickness AND Yield strength
dc.treeJournal of Pressure Vessel Technology:;1977:;volume( 099 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record