| dc.contributor.author | Charles O. Smith | |
| dc.date.accessioned | 2017-05-08T23:02:58Z | |
| dc.date.available | 2017-05-08T23:02:58Z | |
| dc.date.copyright | January, 1977 | |
| dc.date.issued | 1977 | |
| dc.identifier.issn | 0094-4289 | |
| dc.identifier.other | JEMTA8-26850#83_1.pdf | |
| dc.identifier.uri | http://yetl.yabesh.ir/yetl/handle/yetl/89941 | |
| dc.description.abstract | This is an account of a welded blower fan assembly which failed in operation with a large detached portion killing the owner. The circumstances, method of fabrication, and mode of operation are discussed. Failure was due to a combination of a design defect and a worn shaft. | |
| dc.publisher | The American Society of Mechanical Engineers (ASME) | |
| dc.title | Failure of a Welded Blower Fan Assembly | |
| dc.type | Journal Paper | |
| dc.journal.volume | 99 | |
| dc.journal.issue | 1 | |
| dc.journal.title | Journal of Engineering Materials and Technology | |
| dc.identifier.doi | 10.1115/1.3443412 | |
| dc.journal.fristpage | 83 | |
| dc.journal.lastpage | 85 | |
| dc.identifier.eissn | 1528-8889 | |
| dc.keywords | Manufacturing | |
| dc.keywords | Failure AND Design | |
| dc.tree | Journal of Engineering Materials and Technology:;1977:;volume( 099 ):;issue: 001 | |
| dc.contenttype | Fulltext | |