• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Feasibility of an Active Control Scheme for Above Knee Prostheses

    Thumbnail
    View/Open
    JBENDY-25540#215_1.pdf (1.261Mb)
    Date
    1977
    Author
    D. L. Grimes
    W. C. Flowers
    M. Donath
    Metadata
    Show full item record
    Abstract
    The level walking process for an above knee (A/K ) amputee with a conventional prosthesis greatly compromises the amputee’s mobility. The fact that conventional prostheses lock in hyperextension during the stance phase, in contrast to the extend-flexextend pattern during stance for the natural limb, has been suggested as a source of the amputee’s uncosmetic gait and high energy expenditure. While the lock in hyperextension during stance provides stability to prevent buckling, it requires the person to vault over the prosthetic limb. This vaulting during level walking may cause higher vertical displacements of the body center of gravity (c.g.) and accompanying higher energy requirements for the amputee. This investigation employs an amputee-interactive prosthesis simulator system to evaluate the viability of controlling the prosthetic knee joint to follow a normal knee position pattern. In order to insure that the amputee-interactive prosthesis simulator system does not introduce gait anomalies, the system was controlled to simulate a conventional prosthesis. This showed that the simulator system has no undesired side effects since data from walking trials with the simulator system in “conventional prosthesis mode” are very similar to data from conventional prostheses in the literature. Then, an active position control scheme which controls the prosthetic knee joint to follow a normal knee position pattern was tested by two young, active amputees in level walking trials. The subjects experienced very little difficulty in walking with the active control scheme and preferred the simulator with the active control scheme to their conventional prostheses. Measured knee power requirements for the scheme indicate that this type of control is feasible without external power sources. However, measurements of the vertical displacement of the body c.g. show little difference between gait with the active control scheme and gait with a conventional prosthesis. It appears that the increased energy requirements for A/K amputees are not due in total to the lack of the extend-flex-extend position profile at the prosthetic knee joint.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/89640
    Collections
    • Journal of Biomechanical Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV