Show simple item record

dc.contributor.authorW. R. Apblett
dc.contributor.authorE. D. Montrone
dc.contributor.authorW. Wolowodiuk
dc.date.accessioned2017-05-08T23:01:39Z
dc.date.available2017-05-08T23:01:39Z
dc.date.copyrightNovember, 1976
dc.date.issued1976
dc.identifier.issn0094-9930
dc.identifier.otherJPVTAS-28139#291_1.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/89181
dc.description.abstractTo prove the inherent integrity of the fillet-type tube-to-tubesheet welds proposed in the initial design of the Intermediate Heat Exchanger for the Liquid Metal Fast Breeder Program Fast Flux Test Facility, a seven-tube model was built with prototypical tubes and welds. The welds were subjected to thermal shocks well in excess, both in severity and numbers, of those that the plant units may be expected to experience. Post-test examinations of the welds confirmed that no failures had occurred during the test. However, minor cracks were observed in the weld root area upon microscopic examination of the weld cross sections. This paper describes the test model and the results obtained from it.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermal Shock Testing of Fillet-Type Tube-to-Tubesheet Welds
dc.typeJournal Paper
dc.journal.volume98
dc.journal.issue4
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.3454414
dc.journal.fristpage291
dc.journal.lastpage297
dc.identifier.eissn1528-8978
dc.keywordsWelded joints
dc.keywordsTesting
dc.keywordsThermal shock
dc.keywordsLiquid metals
dc.keywordsCross section (Physics)
dc.keywordsShock (Mechanics)
dc.keywordsFailure
dc.keywordsIndustrial plants
dc.keywordsTest facilities
dc.keywordsFracture (Materials)
dc.keywordsDesign AND Heat exchangers
dc.treeJournal of Pressure Vessel Technology:;1976:;volume( 098 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record