Show simple item record

dc.contributor.authorYunfeng Zhang
dc.contributor.authorSongye Zhu
dc.date.accessioned2017-05-08T22:41:20Z
dc.date.available2017-05-08T22:41:20Z
dc.date.copyrightMarch 2008
dc.date.issued2008
dc.identifier.other%28asce%290733-9399%282008%29134%3A3%28240%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/86537
dc.description.abstractThis paper presents a simulation-based benchmark control study in which shape memory alloy (SMA) wire dampers are utilized to control the seismic response of a three-story nonlinear steel frame building. The SMA wire damper uses superelastic Nitinol wires for energy dissipation because of its high fatigue life and large recoverable strain. An analytical model which considers the training effect of SMA wires is used to describe the stress-strain relationship of superelastic SMA wires. The performance of SMA wire dampers is investigated in the framework of the third-generation benchmark problem on structural control. A comparative study of the seismic response control performance of SMA wire dampers with either unprestrained or prestrained SMA wires was also conducted. The results of this simulation-based benchmark control study show that SMA wire dampers, as a passive structure control measure, can effectively reduce the seismic responses of the three-story nonlinear benchmark building structure and has the potential to withstand several design earthquakes without the need for repair.
dc.publisherAmerican Society of Civil Engineers
dc.titleSeismic Response Control of Building Structures with Superelastic Shape Memory Alloy Wire Dampers
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue3
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(2008)134:3(240)
dc.treeJournal of Engineering Mechanics:;2008:;Volume ( 134 ):;issue: 003