Show simple item record

dc.contributor.authorRichard E. Christenson
dc.contributor.authorB. F. Spencer Jr.
dc.contributor.authorErik A. Johnson
dc.date.accessioned2017-05-08T22:40:50Z
dc.date.available2017-05-08T22:40:50Z
dc.date.copyrightMarch 2006
dc.date.issued2006
dc.identifier.other%28asce%290733-9399%282006%29132%3A3%28268%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/86220
dc.description.abstractStay cables, such as are used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Transversely attached passive viscous dampers have been implemented in many bridges to dampen such vibration. However, only minimal damping can be added if the attachment point is close to the bridge deck. For longer bridge cables, the relative attachment point becomes increasingly smaller, and passive damping may become insufficient. A recent analytical study by the authors demonstrated that “smart” semiactive damping can provide increased supplemental damping. This paper experimentally verifies a smart damping control strategy employing
dc.publisherAmerican Society of Civil Engineers
dc.titleExperimental Verification of Smart Cable Damping
dc.typeJournal Paper
dc.journal.volume132
dc.journal.issue3
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(2006)132:3(268)
dc.treeJournal of Engineering Mechanics:;2006:;Volume ( 132 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record