Show simple item record

dc.contributor.authorNadathur Varadarajan
dc.contributor.authorSatish Nagarajaiah
dc.date.accessioned2017-05-08T22:40:22Z
dc.date.available2017-05-08T22:40:22Z
dc.date.copyrightApril 2004
dc.date.issued2004
dc.identifier.other%28asce%290733-9399%282004%29130%3A4%28451%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/85906
dc.description.abstractThe effectiveness of a novel semiactive variable stiffness-tuned mass damper (SAIVS-TMD) for the response control of a wind-excited tall benchmark building is investigated in this study. The benchmark building considered is a proposed 76-story concrete office tower in Melbourne, Australia. It is a slender building 306 m tall with a height to width ratio of 7.3; hence, it is wind sensitive. Across wind load data from wind tunnel tests are used in the present study. The objective of this study is to evaluate the new SAIVS-TMD system, that has the distinct advantage of continuously retuning its frequency due to real time control and is robust to changes in building stiffness and damping. In comparison, the passive tuned mass damper (TMD) can only be tuned to a fixed frequency. A time varying analytical model of the tall building with the SAIVS-TMD is developed. The frequency tuning of the SAIVS-TMD is achieved based on empirical mode decomposition and Hilbert transform instantaneous frequency algorithm developed by the writers. It is shown that the SAIVS-TMD can reduce the structural response substantially, when compared to the uncontrolled case, and it can reduce the response further when compared to the case with TMD. Additionally, it is shown the SAIVS-TMD reduces response even when the building stiffness changes by ±15% and is robust; whereas, the TMD loses its effectiveness under such building stiffness variations. It is also shown that SAIVS-TMD can reduce the response similar to an active TMD; however, with an order of magnitude less power consumption.
dc.publisherAmerican Society of Civil Engineers
dc.titleWind Response Control of Building with Variable Stiffness Tuned Mass Damper Using Empirical Mode Decomposition/Hilbert Transform
dc.typeJournal Paper
dc.journal.volume130
dc.journal.issue4
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(2004)130:4(451)
dc.treeJournal of Engineering Mechanics:;2004:;Volume ( 130 ):;issue: 004