Show simple item record

dc.contributor.authorAkira Fukukita
dc.contributor.authorTomoo Saito
dc.contributor.authorKeiji Shiba
dc.date.accessioned2017-05-08T22:40:22Z
dc.date.available2017-05-08T22:40:22Z
dc.date.copyrightApril 2004
dc.date.issued2004
dc.identifier.other%28asce%290733-9399%282004%29130%3A4%28430%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/85903
dc.description.abstractIn this paper, we study the control effect for a 20-story benchmark building and apply passive and semiactive control devices to the building. First, we take viscous damping walls as a passive control device which consists of two outer plates and one inner plate, facing each other with a small gap filled with viscous fluid. The damping force is related to the interstory velocity, temperature, and the shearing area. Next, we take a variable oil damper as a semiactive control device which can produce the control forces by little electrical power. We propose a damper model in which the damping coefficient changes according to the response of the damper and control forces calculated by the controller based on a linear quadratic Gaussian control theory. It is demonstrated from the results of some simulations that both passive device and semiactive device can effectively reduce the response of the structure in various earthquake motions.
dc.publisherAmerican Society of Civil Engineers
dc.titleControl Effect for 20-Story Benchmark Building Using Passive or Semiactive Device
dc.typeJournal Paper
dc.journal.volume130
dc.journal.issue4
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(2004)130:4(430)
dc.treeJournal of Engineering Mechanics:;2004:;Volume ( 130 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record