dc.description.abstractA new control algorithm is proposed in this paper to control the responses of a seismically excited, nonlinear 20-story building with piezoelectric friction dampers. The passive friction damping mechanism is used for low-amplitude vibration while the active counterpart takes over for high-amplitude vibration. Both the stick and sliding phases of dampers are taken into account. To effectively mitigate the peak story drift and floor acceleration of the 20-story building, multiple dampers are placed on the 20-story building based on a sequential procedure developed for optimal performance of the dampers. Extensive simulations indicate that the proposed semiactive dampers can effectively reduce the seismic responses of the uncontrolled building with substantially less external power than its associated active dampers, for instance, 67% less under the 1940 El Centro earthquake when the passive friction force is equal to 10% of the damper capacity.
dc.publisherAmerican Society of Civil Engineers
dc.titleSemiactive Control of the 20-Story Benchmark Building with Piezoelectric Friction Dampers
dc.typeJournal Paper
dc.journal.volume130
dc.journal.issue4
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(2004)130:4(393)
dc.treeJournal of Engineering Mechanics:;2004:;Volume ( 130 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record