Show simple item record

dc.contributor.authorZongcai Deng
dc.contributor.authorQingbin Li
dc.contributor.authorAnquan Jiu
dc.contributor.authorLei Li
dc.date.accessioned2017-05-08T22:40:07Z
dc.date.available2017-05-08T22:40:07Z
dc.date.copyrightJune 2003
dc.date.issued2003
dc.identifier.other%28asce%290733-9399%282003%29129%3A6%28697%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/85757
dc.description.abstractThe behavior of a concrete specimen uniaxially embedded with a shape memory alloy (SMA) wire actuated by electrical current is studied in this paper. The main factors influencing the axial strain of the concrete specimen were examined through a sophisticated experimental program. The experimental results indicate that the SMA actuator can be employed as a way of prestressing for axial concrete specimens and can be used for controlling axial strain of concrete specimens. Also the influences of initial prestrain of SMA wires, modes activating electrical current, the actuation times, etc., on the axial strain behavior of concrete specimen are significant.
dc.publisherAmerican Society of Civil Engineers
dc.titleBehavior of Concrete Driven by Uniaxially Embedded Shape Memory Alloy Actuators
dc.typeJournal Paper
dc.journal.volume129
dc.journal.issue6
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(2003)129:6(697)
dc.treeJournal of Engineering Mechanics:;2003:;Volume ( 129 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record