NSM CFRP Strengthening and Failure Loading of a Posttensioned Concrete Bridge
View/ Open
Date
2016Author
Jonny Nilimaa
Niklas Bagge
Thomas Blanksvärd
Björn Täljsten
Metadata
Show full item recordAbstract
Two carbon-fiber-reinforced polymer (CFRP) systems developed as possible means to strengthen existing concrete structures have been applied to a bridge at Kiruna (Sweden). The bridge was no longer in service and was thus used in extensive tests to failure. It was a posttensioned five-span bridge consisting of three longitudinal main girders topped with a concrete slab. The program reported here consisted of a series of three tests of the girders in the second span: loading each girder up to 2.0 MN before strengthening, loading each girder up to 2.0 MN after strengthening, and loading to failure after strengthening. One of the girders was strengthened by installing three