Error Analysis for Pseudodynamic Test Method. II: Application
Abstract
Error propagation characteristics for the pseudodynamic test method based on implicit time‐integration schemes are evaluated and compared to those for an explicit time‐integration scheme. For random errors and a linear structure with one degree of freedom, the error amplification factor for the implicit scheme is generally lower than that for the explicit scheme. The difference is small when the time step is small compared to the period of oscillation of the structure, and increases for larger time steps. The advantages of the implicit scheme become more apparent for an