| dc.description.abstract | Monitoring of measurements needs to be supported by a thorough knowledge of the achievable accuracy of the measurement equipment and the processing methodology. This study on ovalization monitoring with laser scanning in tunnels under construction focused on fast-performing laser scanners and their achievable accuracy. This research also investigated the optimum smoothing level of the laser scanning data to achieve the best estimates of ovalization. The experimentally based standard deviations indicate that the used phase-based laser scanner delivers highly accurate results with standard deviations between 0.34 and 0.58 mm, depending on the applied smoothing level. In this research, this laser scanner was used, together with a [ | |
| dc.publisher | American Society of Civil Engineers | |
| dc.title | Laser Scanning for Precise Ovalization Measurements: Standard Deviations and Smoothing Levels | |
| dc.type | Journal Paper | |
| dc.journal.volume | 142 | |
| dc.journal.issue | 4 | |
| dc.journal.title | Journal of Surveying Engineering | |
| dc.identifier.doi | 10.1061/(ASCE)SU.1943-5428.0000165 | |
| dc.tree | Journal of Surveying Engineering:;2016:;Volume ( 142 ):;issue: 004 | |
| dc.contenttype | Fulltext | |