    Buckling of Built‐Up Columns with or without stay plates

    Thumbnail
    View/Open
    %28asce%290733-9399%281990%29116%3A5%281142%29.pdf (836.1Kb)
    Date
    1990
    Author
    Atle Gjelsvik
    Metadata
    Show full item record
    Abstract
    A method of analysis for built‐up columns is presented. The method is an extension of the classical Engesser method for columns and the Timoshenko shear‐beam theory for beams. The two column chords are treated as beams connected by a shear panel simulating the web. The governing differential equation changes from a fourth‐ to a sixth‐order equation with a corresponding increase in the number of boundary conditions. It then becomes possible to include the effect of stay plates on the buckling load in a rational manner. It is found that the stay plates have a very significant effect on the buckling load. It is also found that the buckling load depends not only on the bending and shear stiffness of the column but also on the relative value of the chords' bending stiffness to the overall column bending stiffness. The solution for a simply supported column is given. The classical Engesser solution is always conservative.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/82453
    Collections
    • Journal of Engineering Mechanics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV