| dc.description.abstract | This paper presents test results of six full-scale glass fiber-reinforced polymer (GFRP) reinforced concrete slab–column edge connections. The test connections included two series with three connections each. The connections of Series 1 investigated the effect of a new type of GFRP shear reinforcement on the punching shear behavior of slab-column edge connections, while those of Series 2 investigated the effect of moment-to-shear ratio. For Series 1, one connection did not have shear reinforcement, while the other two connections had ribbed-deformed GFRP shear studs with headed ends at different radial spacing (120 and 80 mm). For Series 2, three different moment-to-shear ratios were applied to the connections (0.2, 0.4, and 0.6 m). The typical dimensions of the slabs were | |