dc.description.abstractThis paper presents test results of six full-scale glass fiber-reinforced polymer (GFRP) reinforced concrete slab–column edge connections. The test connections included two series with three connections each. The connections of Series 1 investigated the effect of a new type of GFRP shear reinforcement on the punching shear behavior of slab-column edge connections, while those of Series 2 investigated the effect of moment-to-shear ratio. For Series 1, one connection did not have shear reinforcement, while the other two connections had ribbed-deformed GFRP shear studs with headed ends at different radial spacing (120 and 80 mm). For Series 2, three different moment-to-shear ratios were applied to the connections (0.2, 0.4, and 0.6 m). The typical dimensions of the slabs were
dc.publisherAmerican Society of Civil Engineers
dc.titleEffect of Shear Studs and High Moments on Punching Behavior of GFRP-RC Slab–Column Edge Connections
dc.typeJournal Paper
dc.journal.volume20
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000668
dc.treeJournal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 004