Show simple item record

dc.contributor.authorB. Zafari
dc.contributor.authorJ. T. Mottram
dc.date.accessioned2017-05-08T22:28:58Z
dc.date.available2017-05-08T22:28:58Z
dc.date.copyrightFebruary 2015
dc.date.issued2015
dc.identifier.other46374532.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/81338
dc.description.abstractPresented in this paper are test results to determine the moment-rotation characteristics of joint details for a portal frame specific to a pultruded fiber reinforced polymer assembly for the Startlink house. Two joints having beam-to-column dowel connections, with and without extra adhesively bonding, were statically loaded in increments of moment or rotation to ultimate failure. The floor beam and stud column members are bespoke closed sections developed for Startlink Lightweight Building System. The serviceability design calculations for the demonstrator house at Bourne, England assumed the joints rigid. Clauses in an English standard are applied to classify the measured rotational stiffnesses against the rigid requirement, and an evaluation is made of the modes of failure with respect to the design moments. Only the joint with extra bonding between the mating surfaces of the members is classified as rigid. Both joints are shown to have an acceptable strength.
dc.publisherAmerican Society of Civil Engineers
dc.titleCharacterization by Full-Size Testing of Pultruded Frame Joints for the Startlink House
dc.typeJournal Paper
dc.journal.volume19
dc.journal.issue1
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000488
dc.treeJournal of Composites for Construction:;2015:;Volume ( 019 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record